Typical Scan Tool Data: Notes
SC Inlet Pressure Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition is ON. Normal SCIP Parameter: BARO - Altitude Versus Barometric Pressure |
|||
| 5-Volt Reference | 8-12 kPa | 8-12 kPa | 96-104 kPa |
| SCIP Sensor Signal | 8-12 kPa | 8-12 kPa | 96-104 kPa |
| Low Reference | - | 96-104 kPa | - |
SC Inlet Pressure Sensor, Volts
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Parameter Normal Range: Engine Running 1.2-1.95 volts | |||
| 5-Volt Reference | 0.04 V | 0.0 V | 4.50-4.98 V |
| SCIP Sensor Signal | 0.0 V | 0.0 V | 4.98 V |
| Low Reference | - | 4.55-4.98 V | - |