LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2006 >> STS V >> Repair and Diagnosis (Single Page) >> Steering >> Steering Wheel & Steering Column >> Diagnostic Information and Procedures >> Scan Tool Data Definitions >> Memory Seat Module (MSM) Scan Tool Data Definitions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Memory Seat Module (MSM) Scan Tool Data Definitions

The Memory Seat Module (MSM) Scan Tool Data Definitions contains a brief description of all steering column related MSM parameters available on the scan tool.

Default Telescope Exit Position

The scan tool displays the default voltage value for the telescope operation in the exit position.

Default Tilt Exit Position

The scan tool displays the default voltage value for the tilt operation in the exit position.

Driver 1 Memorized Position (Telescope)

The scan tool displays 0-5 volts. The value displayed is the telescope sensor voltage stored by the MSM and is used to recall the telescope position for driver 1.

Driver 1 Memorized Position (Tilt)

The scan tool displays 0-5 volts. The value displayed is the telescope sensor voltage stored by the MSM and is used to recall the tilt position for driver 1.

Driver 2 Memorized Position (Telescope)

The scan tool displays 0-5 volts. The value displayed is the telescope sensor voltage stored by the MSM and is used to recall the telescope position for driver 2.

Driver 2 Memorized Position (Tilt)

The scan tool displays 0-5 volts. The value displayed is the telescope sensor voltage stored by the MSM and is used to recall the tilt position for driver 2.

Memory 1 Telescope Exit Position

The scan tool displays 0-5 volts. The value displayed is the telescope sensor voltage stored by the MSM and is used to recall the telescope exit position for driver 1.

Memory 1 Tilt Exit Position

The scan tool display 0-5 volts. The value displayed is the tilt sensor voltage stored by the MSM and is used to recall the tilt exit position for driver 1.

Memory 2 Telescope Exit Position

The scan tool displays 0-5 volts. The value displayed is the telescope sensor voltage stored by the MSM and is used to recall the telescope exit position for driver 2.

Memory 2 Tilt Exit Position

The scan tool display 0-5 volts. The value displayed is the tilt sensor voltage stored by the MSM and is used to recall the tilt exit position for driver 2.

Telescope Forward Command

The scan displays On or Off. The scan tool displays On when the MSM commands the telescope actuator forward.

Telescope Rearward Command

The scan displays On or Off. The scan tool displays On when the MSM commands the telescope actuator rearward.

Telescope Sensor

The scan tool displays 0-5 volts. The value displayed is the telescope sensor signal voltage. This voltage varies when the steering column is moved forward or rearward and is used by the MSM to determine the steering column position when memory settings are stored and recalled.

Telescope Soft Stops Learned

The scan tool displays Yes if the telescope soft stops have been learned. If the scan tool displays No, the learn procedure must be performed.

Tilt Down Command

The scan displays On or Off. The scan tool displays On when the MSM commands the tilt actuator down.

Tilt Sensor

The scan tool displays 0-5 volts. The value displayed is the tilt sensor signal voltage. This voltage varies when the steering column is moved up or down and is used by the MSM to determine the steering column position when memory settings are stored and recalled.

Tilt Soft Stops Learned

The scan tool displays Yes if the tilt soft stops have been learned. If the scan tool displays No, the learn procedure must be performed.