Installation Procedure
- Clean the seal surface of the BPMV (2).
- Make sure that the internal pump motor connector (3) is installed into the new EBCM (1) prior to EBCM replacement.
- Install the EBCM (1) to the BPMV (2).
- Install the 4 EBCM to BPMV screws.
Tighten: Tighten the 4 EBCM to BPMV screws in sequence (1-4) to 5 N.m (44 lb in).
- Connect the EBCM electrical connector (1) to the EBCM (3).
- Rotate the EBCM connector tab (2) rearward to the locked position.
- Install the washer solvent container bracket. Refer to Solvent Container, Pump, Level Sensor Replacement - Windshield Washer in Wipers/Washer Systems.
- Install the wheelhouse liner. Refer to Front Wheelhouse Liner Replacement in Body Front End.
- Install the air deflector shield. Refer to Front Air Deflector Replacement in Body Front End.
- Lower the vehicle.
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
- If installing a new EBCM it is necessary to program the EBCM. Refer to Service Programming System (SPS) in Programming and Setup.
- Perform the Diagnostic System Check - Vehicle. Refer to Diagnostic System Check - Vehicle in Vehicle DTC Information.
- Refer to Control Module References for programming and setup information.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.
NOTE:
To prevent equipment damage, never connect or disconnect the wiring harness connection from the EBCM with the ignition switch in the ON position.