Typical Scan Tool Data
SC Inlet Pressure Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition ON, engine OFF Normal Parameter Range: Varies 30-125 kPa |
|||
| 5-Volt Reference | 8-10 kPa | 8-10 kPa | 100-210 kPa |
| SCIP Sensor Signal | 8-10 kPa | 8-10 kPa | 100-210 kPa |
| Low Reference | - | 90-107 kPa | - |
BARO Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition ON, engine OFF Normal Parameter Range BARO-Refer to Altitude Versus Barometric Pressure |
|||
| 5-Volt Reference Circuit | 8-10 kPa | 8-10 kPa | 200-208 kPa |
| Sensor Signal Circuit | 8-10 kPa | 8-10 kPa | 200-208 kPa |
| Low Reference | - | 191 kPa | - |