Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the MAP sensor.
- Ignition OFF, test for less than 5 ohms of resistance between the low reference circuit terminal and ground.
- If greater than the specified range, test the low reference circuit for an open or high resistance. If the circuit tests normal, replace the control module.
- Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal and ground.
- If less than the specified range, test the 5-volt reference circuit for a short to ground, open, or high resistance. If the circuit tests normal, replace the control module.
- If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the control module.
- Verify the scan tool MAP Sensor parameter is less than 0.2 volt.
- If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the control module.
- Install a 3A fused jumper wire between the signal circuit terminal and the 5-volt reference terminal. Verify the scan tool MAP Sensor parameter is greater than 200 kPa.
- If less than the specified range, test the signal circuit for a short to ground, open, or high resistance. If the circuit tests normal, replace the control module.
- If all circuits test normal, test the MAP sensor. Refer to Component Testing
IMPORTANT:
You must perform the circuit/system verification before proceeding with the circuit/system testing.