Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the MAP sensor.
- Ignition OFF, allow sufficient time for the control module to power down. Measure for less than 5 ohms of resistance between the low reference circuit of the connector and a good ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit and ground.
- If less than the specified range, test the 5-volt reference circuit for an open/high resistance or a short to ground. If the circuit tests normal, replace the ECM.
- If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Verify the scan tool MAP sensor voltage parameter is less than 13 kPa.
- If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Install a 3A fused jumper wire between the signal circuit and the 5-volt reference circuit. Verify the scan tool MAP sensor parameter is greater than 253 kPa.
- If less than the specified range, test the sensor signal circuit for high resistance.
- If all circuits test normal, test the MAP sensor. Refer to Component Test.