Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the SCIP sensor.
- Ignition ON, allow sufficient time for the ECM to power down. Test for less than 2 ohms of resistance between the low reference circuit and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit and ground.
- If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Verify the scan tool SC Inlet Pressure Sensor parameter is less than 20 kPa.
- If the greater than the specified parameter, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Install a 3-amp fused jumper wire between the 5-volt reference circuit and the signal circuit. Verify the scan tool parameter is greater than 100 kPa.
- If less than the specified parameter, test the signal circuit for a short to ground, open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test the SCIP sensor.