Typical Scan Tool Data
AIR Pressure Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Key ON, Engine OFF Normal Operation Range: BARO Refer to Altitude Versus Barometric Pressure . |
|||
| 5-Volt Reference Voltage | 41 kPa | 41 kPa | 111 kPa |
| Pressure Sensor Signal | 41 kPa | 41 kPa | 145 kPa |
| Low Reference | BARO | 145 kPa | - |