Circuit/System Testing
- If the DTC is history, refer to Charging System Test .
- If the DTC is current, turn ON the ignition, and with a DMM, measure the voltage between the battery positive voltage circuits of the affected module and the ground circuits of the affected module.
- If the voltage is within 9-18 volts, replace the affected module.
- If the voltage is not within 9-18 volts, measure the voltage between the battery positive voltage circuits of the affected module and a separate good ground.
- If the voltage is within 9-18 volts, test the battery positive ground circuits of the affected module for high resistance or an open, and repair as necessary.