Battery Rundown Protection/Inadvertent Power
The BCM inadvertent power courtesy lamps supply voltage circuit provides battery positive voltage to all of the interior reading lamps, I/P compartment lamp, underhood lamp, and both visor vanity mirror lamps. In the event that any of these lamps were to remain illuminated for a period of more than 20 minutes with the ignition switch in the OFF position, the BCM will deactivate the inadvertent power courtesy lamps supply voltage circuit to prevent a total battery discharge condition. Only when the ignition switch is cycled back to the RUN position will the BCM reset the internal timer and reactivate the inadvertent power courtesy lamps supply voltage circuit.
The BCM also utilizes the inadvertent power courtesy lamps supply voltage circuit as a courtesy lamp request signal circuit when none of the lamps in the circuit are illuminated. When a lamp switch is activated, the BCM receives the request for lamp illumination and switches to supplying voltage to the inadvertent power courtesy lamps supply voltage circuit.