Scan Tool Data List

WARNING: This page is about a different car, the 2007 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Engine Control Module (ECM) Hybrid

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Ignition ON/Engine OFF/Hood Open
12V Battery Current Engine Control Module, Data Display, Hybrid Data, Data Display Amps 0 amps
12V Batt. Est. Temp. Engine Control Module, Data Display, Hybrid Data, Data Display Celsius/Fahrenheit 82 degrees F
APM Control Mode Engine Control Module, Data Display, Hybrid Data, Data Display Off, High to Low, Low to High, Not Used Off
APM Control Status Engine Control Module, Data Display, Hybrid Data, Data Display Charging, Current Limited, Shutdown, Not Used Normal Change
APM Desired Voltage Engine Control Module, Data Display, Hybrid Data, Data Display Volts 14 volts
APM Voltage Engine Control Module, Data Display, Hybrid Data, Data Display Volts 12 volts
Aux. Trans Fluid Pump Command Engine Control Module, Data Display, Hybrid Data, Data Display Percent 0 percent
Aux Trans Fluid Pump Relay Engine Control Module, Data Display, Hybrid Data, Data Display On/Off On
Contactor Open Reason Engine Control Module, Data Display, Hybrid Data, Data Display None, SDM Command, Service Discon., ECM Discon., Hybrid Batt Tem, Fault None
Desired Hybrid Batt. SOC Engine Control Module, Data Display, Hybrid Data, Data Display Percent 69 percent
Desired Starter Gen Torque Engine Control Module, Data Display, Hybrid Data, Data Display N.m  
12 N.m
ECM Desired Contactor Position Engine Control Module, Data Display, Hybrid Data, Data Display Closed, Open Closed
Economy Lamp Command Engine Control Module, Data Display, Hybrid Data, Data Display On/Off Off
Eng Auto Start Reason Engine Control Module, Data Display, Hybrid Data, Data Display None, BPP, APP, Trans Range Tim, Auto Stop Time, Hybrid Batt Stat, Aux TFP Pump, Coast Speed Low, Coast Speed High, BBC Low, Coast Speed Inc, 12V Batt Hi Amp, 12V Batt Lo Amp, Fault, ECT Low, Device Control, A/C Request, ECT High, Engine Control None
Hill Hold Lamp Command Engine Control Module, Data Display, Hybrid Data, Data Display On/Off Off
Hood Switch Indicated Position Engine Control Module, Data Display, Hybrid Data, Data Display Closed/Ajar/Open Open
Hybrid Batt Avg Cell Temp. Engine Control Module, Data Display, Hybrid Data, Data Display Celsius/Fahrenheit 73 degrees F
Hybrid Batt Max Cell Temp. Engine Control Module, Data Display, Hybrid Data, Data Display Celsius/Fahrenheit 75 degrees F
Hybrid Batt Min Cell Temp. Engine Control Module, Data Display, Hybrid Data, Data Display Celsius/Fahrenheit 73 degrees F
Hybrid Batt Power Available Engine Control Module, Data Display, Hybrid Data, Data Display Watts 13,616.0 watts
Hybrid Battery Current Engine Control Module, Data Display, Hybrid Data, Data Display Amps 0.0 amps
Hybrid Battery Internal Resistance Engine Control Module, Data Display, Hybrid Data, Data Display Ohms 0 ohms
Hybrid Battery SOC Engine Control Module, Data Display, Hybrid Data, Data Display Percent 60 percent
Hybrid Battery Voltage Engine Control Module, Data Display, Hybrid Data, Data Display Volts 39.67 volts
Hybrid Mode Status Engine Control Module, Data Display, Hybrid Data, Data Display Hybrid DFCO, Regen Braking, Auto Start, Auto Stop, Fault Active, Key Crank Required, Key Crank Active Hybrid DFCO
Ignition 1 Signal Engine Control Module, Data Display, Hybrid Data, Data Display Volts 12 volts
Last Start Method Engine Control Module, Data Display, Hybrid Data, Data Display Starter GEN, 12V Starter, Tandem Starter 12V Starter
SGCM Coolant Pump Relay Command Engine Control Module, Data Display, Hybrid Data, Data Display Off/On Off
SGCM Des. Contactor Position Engine Control Module, Data Display, Hybrid Data, Data Display Closed/Open Closed
SGCM Temperature Engine Control Module, Data Display, Hybrid Data, Data Display Celsius/Fahrenheit 75 degrees F
Starter Gen. Belt Slip Engine Control Module, Data Display, Hybrid Data, Data Display Percent -100 percent
Starter Genenerator Calculated Torque Engine Control Module, Data Display, Hybrid Data, Data Display N.m 8.9 N.m
Starter Generator Mode Engine Control Module, Data Display, Hybrid Data, Data Display Neutral, CKP Indexing, Key Crank Active, Auto Start, Transition, Charging, Discharging, Regen Braking, Accel Boost, Spin Dwn Control Neutral
Starter Generator Speed Engine Control Module, Data Display, Hybrid Data, Data Display RPM 0 RPM
Starter/Generator Control Module (SGCM)

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Ignition ON/Engine OFF/Hood Open
14 Volt Power Module Output Current Starter/Generator Control Module, SGCM Data Display, Data Display Amps 0.0 amps
14 Volt Power Module Output Voltage Starter/Generator Control Module, SGCM Data Display, Data Display Volts 13.9 volts
14 Volt Power Module Temperature Starter/Generator Control Module, SGCM Data Display, Data Display Degrees 73 degrees F
APM Control Command Mode Starter/Generator Control Module, SGCM Data Display, Data Display Off, High to Low, Low to High, Not Used Off
APM Control Status Starter/Generator Control Module, SGCM Data Display, Data Display Charging, Current Limited, Shutdown, Not Used Charging
APM Desired Voltage Starter/Generator Control Module, SGCM Data Display, Data Display Volts 12.07 volts
Aux Trans Fluid Pump Relay Starter/Generator Control Module, SGCM Data Display, Data Display On/Off On
Engine Speed Starter/Generator Control Module, SGCM Data Display, Data Display RPM 0 RPM
Hood Ajar Switch 1 Starter/Generator Control Module, SGCM Data Display, Data Display Open/Closed Closed
Hood Ajar Switch 2 Starter/Generator Control Module, SGCM Data Display, Data Display Open/Closed Open
Hood Position Starter/Generator Control Module, SGCM Data Display, Data Display Open, Closed Closed
Hybrid System Voltage Starter/Generator Control Module, SGCM Data Display, Data Display Volts 39.7 volts
Starter/Generator Control Module Motor Electronics Temperature Starter/Generator Control Module, SGCM Data Display, Data Display Degrees 84 degrees F
Starter/Generator Inverter Temperature Starter/Generator Control Module, SGCM Data Display, Data Display Celcius/Farenheit 75 degrees F
Starter/Generator Temperature Starter/Generator Control Module, SGCM Data Display, Data Display Celcius/Farenheit 77 degrees F
Starter Generator Field Circuit Starter/Generator Control Module, SGCM Data Display, Data Display Disable, Enable Enable
Starter Generator Field Current Starter/Generator Control Module, SGCM Data Display, Data Display Amps 0.0 amps
Starter Generator Position Starter/Generator Control Module, SGCM Data Display, Data Display Degrees 16 degrees
Starter Generator Speed Starter/Generator Control Module, SGCM Data Display, Data Display RPM 0 RPM
Starter Generator Speed Commanded Starter/Generator Control Module, SGCM Data Display, Data Display RPM 0 RPM
Battery Energy Control Module (BECM)

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Ignition ON/Engine OFF/Hood Open
14 Volt Power Module Output Voltage Battery Energy Control Module, BECM Data Display, Data Display Volts 11.7 volts
Hybrid Batery High Current Sensor Battery Energy Control Module, BECM Data Display, Data Display Volts 3.3 volts
Hybrid Battery High Current Sensor Battery Energy Control Module, BECM Data Display, Data Display Amps 0.0 amps
Hybrid Battery Low Current Sensor Battery Energy Control Module, BECM Data Display, Data Display Volts 2.5 volts
Hybrid Battery Low Current Sensor Battery Energy Control Module, BECM Data Display, Data Display Amps 0.0 amps
Hybrid Battery 1 Temperature Battery Energy Control Module, BECM Data Display, Data Display Celsius/Fahrenheit 75 degrees F
Hybrid Battery 2 Temperature Battery Energy Control Module, BECM Data Display, Data Display Celsius/Fahrenheit 75 degrees F
Hybrid Battery 3 Temperature Battery Energy Control Module, BECM Data Display, Data Display Celsius/Fahrenheit 75 degrees F
Hybrid Battery 4 Temperature Battery Energy Control Module, BECM Data Display, Data Display Celsius/Fahrenheit 75 degrees F
Hybrid Battery 5 Temperature Battery Energy Control Module, BECM Data Display, Data Display Celsius/Fahrenheit 75 degrees F
Hybrid Battery 6 Temperature Battery Energy Control Module, BECM Data Display, Data Display Celsius/Fahrenheit 75 degrees F
Hybrid Battery 1 Temperature Sensor Battery Energy Control Module, BECM Data Display, Data Display Volts 1.9 volts
Hybrid Battery 2 Temperature Sensor Battery Energy Control Module, BECM Data Display, Data Display Volts 1.9 volts
Hybrid Battery 3 Temperature Sensor Battery Energy Control Module, BECM Data Display, Data Display Volts 1.9 volts
Hybrid Battery 4 Temperature Sensor Battery Energy Control Module, BECM Data Display, Data Display Volts 1.9 volts
Hybrid Battery 5 Temperature Sensor Battery Energy Control Module, BECM Data Display, Data Display Volts 1.9 volts
Hybrid Battery 6 Temperature Sensor Battery Energy Control Module, BECM Data Display, Data Display Volts 1.9 volts
Hybrid Battery Circuit 1 Battery Energy Control Module, BECM Data Display, Data Display Volts 13.2 volts
Hybrid Battery Circuit 2 Battery Energy Control Module, BECM Data Display, Data Display Volts 13.2 volts
Hybrid Battery Circuit 3 Battery Energy Control Module, BECM Data Display, Data Display Volts 13.2 volts
Hybrid Battery Current Sensor Performance Battery Energy Control Module, BECM Data Display, Data Display Zero Range, DC/AC Polarity, High/Low Sensor Zero Range
Hybrid Battery Fan Commanded Battery Energy Control Module, BECM Data Display, Data Display Percent 0 percent
Hybrid Battery Pack Cooling Fan Battery Energy Control Module, BECM Data Display, Data Display RPM 0 RPM
Hybrid Battery Positive Contactor Status Battery Energy Control Module, BECM Data Display, Data Display Closed, Open Impact DTC, Open Service Dis, ECM Fault, Overtemp, Fault Closed
Hybrid Battery Sensor Battery Energy Control Module, BECM Data Display, Data Display Amps 0.0 amps
Hybrid Battery System Voltage Battery Energy Control Module, BECM Data Display, Data Display Volts 39.6 volts
Hybrid System Voltage Battery Energy Control Module, BECM Data Display, Data Display Volts 39.9 volts