LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2007 >> Escalade EXT >> Repair and Diagnosis >> Quick Lookups >> Technical Bulletins >> Technical Service Bulletins >> Mirrors >> Inside Rearview Mirror Ambient Temperature Display Inaccurate Or Will Not Update Properly (Reprogram HVAC Control Module) (07-01-39-003)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Inside Rearview Mirror Ambient Temperature Display Inaccurate Or Will Not Update Properly (Reprogram HVAC Control Module) (07-01-39-003)

Publication date: 2007-04-18
Reference number: 07-01-39-003

Inside Rearview Mirror Ambient Temperature Display Inaccurate Or Will Not Update Properly (Reprogram HVAC Control Module)

Inside Rearview Mirror Ambient Temperature Display Inaccurate Or Will Not Update Properly (Reprogram HVAC Control Module)

TECHNICAL SERVICE BULLETIN

Reference Number(s): 07-01-39-003, Date of Issue:  April 18, 2007
Affected Model(s): 2007 Cadillac Escalade Models; with Automatic Dimming Rearview Mirror with Intellibeam(R), OnStar(R), Compass and Temperature Display (RPO DF5) and Intellibeam(R) High Beam Control (RPO TQ5)

Condition

Some customers may comment on an inaccurate ambient temperature display on the inside rearview mirror. Others may comment that the ambient temperature display does not update properly.

Correction

Correction

Do This Don't Do This
Reprogram the HVAC Control Module. Do not replace the inside rearview mirror or the ambient temperature sensor.

A revised calibration has been developed to address these conditions. Technicians are to reprogram the Heating, Ventilation and Air Conditioning (HVAC) Control Module, using the Service Programming System (SPS), with the latest software available on TIS2WEB. Refer to the HVAC Control Module Programming and Setup procedure in SI (Document ID# 1741202). As always, make sure your Tech 2(R) is updated with the latest software version.

Warranty Information

For vehicles repaired under warranty, use:

Warranty Information

Labor Operation Description Labor Time
D4707* HVAC Control Head Module or Assembly Reprogramming with SPS 0.4 hr
*This labor operation number is for bulletin use only. The number will not be published in the Labor Time Guide.