Installation Procedure
- Clean the seal surface of the BPMV (2).
- Make sure that the internal pump motor connector (3) is installed into the new EBCM (1) prior to EBCM replacement.
- Install the EBCM (1) to the BPMV (2).
- Install the 4 EBCM to BPMV screws.
Tighten: Tighten the 4 EBCM to BPMV screws in sequence (1-4) to 5 N.m (44 lb in).
- Connect the EBCM electrical connector (1) to the EBCM (3).
- Rotate the EBCM connector tab (2) rearward to the locked position.
- Install the washer solvent containert. Refer to Washer Solvent Container Replacement (w/o CE4) or Washer Solvent Container Replacement (w CE4) .
- Install the air deflector shield. Refer to Front Air Deflector Replacement .
- Lower the vehicle.
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
- If installing a new EBCM it is necessary to program the EBCM. Refer to Control Module References .
- Perform the Diagnostic System Check - Vehicle. Refer to Diagnostic System Check - Vehicle .
NOTE:
Refer to Fastener Notice
.
NOTE:
To prevent equipment damage, never connect or disconnect the wiring harness connection from the EBCM with the ignition switch in the ON position.