HVAC Control Module Scan Tool Data Parameters
| Parameter | System State | Expected Value | Description |
|---|---|---|---|
| Operating Conditions: Ignition ON, HVAC OFF | |||
| A/C Request | - | No | The scan tool displays Yes or No. Yes is displayed if the air conditioner is requested. |
| Ambient Air Temp. Sensor | - | Varies | This displays °F (°C). This is the current temperature at the ambient air temperature sensor. |
| Ambient Light Sensor | - | Varies | This displays Counts. This is the current ambient light measured in counts at the ambient light sensor. |
| Blower Motor Speed | - | 0% | This displays %. This is the current blower motor speed measured in percentage. |
| Blower Motor Speed Command | - | 0% | This displays %. This is the commanded blower motor speed measured in percentage. |
| Driver Program Number | - | Varies | This displays Counts. This is the driver program number measured in counts. |
| Driver Temp. Dr. Cal. Range | - | Varies | This displays Pulses. This is the driver temperature door calibration range measured in pulses. |
| Driver Temp. Dr. Motor Command | - | Varies | This displays Counts. This is the commanded driver temperature door motor request measured in counts. |
| Driver Temp. Dr. Position | - | Varies | This displays Counts or Pulses. This is the current driver temperature door position measured in either counts or pulses. |
| Inside Air Temp. Sensor | - | Varies | This displays °F (°C). This is the current temperature at the inside air temperature sensor. |
| LED Intensity | - | Varies | This displays Counts. This is the light emitting diode (LED) intensity measured in counts. |
| Left Sunload Sensor | - | Varies | This displays Counts. This is the current sunload measured in counts at the driver sunload sensor. |
| Load Management Status | - | Off | The scan tool displays On or Off. This is the status of the load management. |
| Lower Left Duct Temp. Sensor | - | Varies | This displays Counts. This is the current temperature at the driver lower duct temperature sensor measured in counts. |
| Lower Right Duct Temp. Sensor | - | Varies | This displays Counts. This is the current temperature at the passenger lower duct temperature sensor measured in counts. |
| Mode Door Position | - | Varies | This displays Counts or Pulses. This is the current mode door position measured in either counts or pulses. |
| Mode Dr. Cal. Range | - | Varies | This displays Pulses. This is the mode door calibration range measured in pulses. |
| Mode Dr. Motor Command | - | Varies | This displays Counts. This is the commanded mode door motor request measured in counts. |
| Mode Status | - | Off | The scan tool displays Off, Auto, Heater, Bi-Level, Defog, Defrost or Mid. This is the current mode of the HVAC system. |
| Psgr. Program Number | - | Varies | This displays Counts. This is the passenger program number measured in counts. |
| Psgr. Temp. Dr. Cal. Range | - | Varies | This displays Pulses. This is the passenger temperature door calibration range measured in pulses. |
| Psgr. Temp. Dr. Motor Command | - | Varies | This displays Counts. This is the commanded passenger temperature door motor request measured in counts. |
| Psgr. Temp. Dr. Position | - | Varies | This displays Counts or Pulses. This is the current passenger temperature door position measured in either counts or pulses. |
| Recirculation Temp. Dr. Cal. Range | - | Varies | This displays Pulses. This is the recirculation temperature door calibration range measured in pulses. |
| Recirculation Temp. Dr. Motor Command | - | Varies | This displays Counts. This is the commanded recirculation temperature door motor request measured in counts. |
| Recirculation Temp. Dr. Position | - | Varies | This displays Counts or Pulses. This is the current recirculation temperature door position measured in either counts or pulses. |
| Right Sunload Sensor | - | Varies | This displays Counts. This is the current sunload measured in counts at the passenger sunload sensor. |
| Seat Temp. Status | - | Off | The scan tool displays Off, Max. Cool, Mid. Cool, Min. Cool, Max. Heat, Mid. Heat or Min. Heat. This is the current state of the driver seat temperature. |
| Upper Left Duct Temp. Sensor | - | Varies | This displays Counts. This is the current temperature at the driver upper duct temperature sensor measured in counts. |
| Upper Right Duct Temp. Sensor | - | Varies | This displays Counts. This is the current temperature at the passenger upper duct temperature sensor measured in counts. |
| Valet Switch | - | Inactive | The scan tool displays Active or Inactive. This is the state of the valet switch. |
| Vehicle Speed | - | 0 km/h (0 mph) | This displays km/h (mph). This is the current vehicle speed. |
HVAC Control Module Scan Tool Output Controls
| Output Control | Description |
|---|---|
| Afterblow Option | When afterblow is activated the scan tool displays an *. |
| Blower Motor | The scan tool displays Off or On selections. This function allows you to command the blower motor to its maximum (100%) or minimum (0%) speeds for 5 seconds. |
| Compressor Clutch | The scan tool displays the A/C compressor clutch status: Engage or Disengage. This function allows you to command the A/C compressor clutch On and Off. |
| Driver Temp. Door | The scan tool displays On or Off selections. The selection drives the actuator to its minimum (cold) or maximum (hot) positions for 20 seconds. |
| Instant OAT Update | The scan tool displays Commanded State: On or Off. This function updates the HVAC control module ambient air temperature input to the current raw value. |
| Mode Door Position | The scan tool displays On or Off selections. This function drives the actuator to its minimum (defrost) or maximum (upper) positions for 20 seconds. |
| Passenger Temp. Door | The scan tool displays On or Off selections. The selection drives the actuator to its minimum (hot) or maximum (cold) positions for 20 seconds. |
| Recalibrate All Motors | When commanded the scan tool displays the actuators counts moving from hot to cold until the re-cal is complete. |
| Recirculation Door | The scan tool displays On or Off selections. This function drives the actuator to its minimum (outside air) or maximum (recirculate) stops for 20 seconds. |