Component Testing
- Ignition OFF, disconnect the harness connector at the RPA display.
- Connect a 10A fused jumper wire between the 12V supply circuit terminal 1 and B+.
- Connect a 10A fused jumper wire between the control circuit terminals listed below and ground.
- Left amber LED control circuit terminal 2
- Center amber LED control circuit terminal 3
- Red LED control circuit terminal 4
- Verify that the appropriate LED illuminates.
- If the component does not perform as specified, replace the RPA display.