Circuit/System Testing
- Using the DTC Descriptor and Diagnostic Aids above, determine the module that is not communicating that should be tested.
- Ignition OFF, disconnect the harness connector of the module that is not communicating.
- Ignition ON, verify that a test lamp illuminates between the high speed GMLAN serial data wake up circuit OR the accessory wake up serial data circuit and ground.
- If the test lamp does not illuminate, test the circuit for an open/high resistance. If the circuits test normal, replace the BCM.
- Ignition ON, verify that a test lamp illuminates between all battery positive voltage circuits and ground.
- If the test lamp does not illuminate, test the circuit for a short to ground or an open/high resistance. If the circuit fuse is open, test the positive voltage outputs of the module for a short to ground. If the circuits test normal, replace the faulty module.
- Verify that a test lamp illuminates between all ignition voltage circuits and ground.
- If the test lamp does not illuminate, test the circuit for a short to ground or an open/high resistance. If the circuit fuse is open, test the positive voltage outputs of the module for a short to ground. If the circuits test normal, replace the faulty module.
- Test for less than 1 ohm of resistance between the module ground circuits and ground.
- If greater than 1 ohm, test the ground circuit for an open.
- Test for less than 1 ohm of resistance in the GMLAN serial data circuit(s) between the non-communicating module and the module that displays the DTC.
- If greater than 1 ohm of resistance, test the GMLAN serial data circuit(s) for open/high resistance.
- If all circuits test normal, replace the module that is not communicating.
IMPORTANT:
If more than one module is not communicating use Data Communication Schematics to determine which module is closest to the DLC. Start diagnostics with that module.
IMPORTANT:
Only the high speed GMLAN modules have a wired serial data wake up circuit. Refer to the module schematics to identify which modules have a wake up circuit. If the module that is not communicating does not have a serial data wake up circuit, proceed to step 4.