Heating, Ventilation and Air Conditioning Control Module Scan Tool Information
HVAC Control Module Scan Tool Data Parameters
| Parameter | System State | Expected Value | Description |
|---|---|---|---|
| Operating Conditions: Ignition ON, HVAC OFF | |||
| A/C Request | - | No | The scan tool displays Yes or No. Yes is displayed if the air conditioner is requested. |
| A/C Evap. Temperature Sensor | - | Varies | This displays °F (°C). This is the current temperature of the evaporator temperature sensor. |
| A/C High Side Pressure Sensor | - | Varies | This displays kPa (psi). The voltage applied to the ECM input from the A/C refrigerant pressure sensor is converted to a pressure value. |
| Ambient Air Temp. Sensor | - | Varies | This displays °F (°C). This is the current temperature at the ambient air temperature sensor. |
| Aux. Mode Door Actual | - | Varies | This displays Counts. This is the current auxiliary mode door position measured in counts. |
| Aux. Mode Door Commanded | - | Varies | This displays Counts. This is the commanded auxiliary mode door motor request measured in counts. |
| Aux. Temp. Dr. Position | - | Varies | This displays Counts. This is the current auxiliary temperature door position measured in counts. |
| Aux. Temp. Dr. Motor Command | - | Varies | This displays Counts. This is the commanded auxiliary temperature door motor request measured in counts. |
| Blower Motor Relay Cmd. | - | Off | This displays the commanded state of the blower motor relay. |
| Blower Motor Speed Command | - | 0% | This displays %. This is the commanded blower motor speed measured in percentage. |
| Coolant Temperature | - | Varies | This displays °F (°C). This is the current temperature of the engine coolant. |
| Driver Temp. Dr. Motor Command | - | Varies | This displays Counts. This is the commanded driver temperature door motor request measured in counts. |
| Driver Temp. Dr. Position | - | Varies | This displays Counts or Pulses. This is the current driver temperature door position measured in either counts or pulses. |
| Inside Air Temp. Sensor | - | Varies | This displays °F (°C). This is the current temperature at the inside air temperature sensor. |
| Left Sunload Sensor | - | Varies | This displays Counts. This is the current sunload measured in counts at the driver sunload sensor. |
| Mode Door Position | - | Varies | This displays Counts or Pulses. This is the current mode door position measured in either counts or pulses. |
| Mode Dr. Motor Command | - | Varies | This displays Counts. This is the commanded mode door motor request measured in counts. |
| Psgr. Temp. Dr. Motor Command | - | Varies | This displays Counts. This is the commanded passenger temperature door motor request measured in counts. |
| Psgr. Temp. Dr. Position | - | Varies | This displays Counts or Pulses. This is the current passenger temperature door position measured in either counts or pulses. |
| Recirculation Dr. Motor Command | - | Varies | This displays Counts. This is the commanded recirculation temperature door motor request measured in counts. |
| Recirculation Dr. Position | - | Varies | This displays Counts or Pulses. This is the current recirculation temperature door position measured in either counts or pulses. |
| Rear Defrost State | - | Off | This displays the current state of the rear defrost switch. |
| Right Sunload Sensor | - | Varies | This displays Counts. This is the current sunload measured in counts at the passenger sunload sensor. |
| Vehicle Speed | - | 0 km/h (0 mph) | This displays km/h (mph). This is the current vehicle speed. |
| Water Pump Relay | - | Off | This displays the current state of the water pump relay. |
HVAC Control Module Scan Tool Output Controls
| Output Control | Description |
|---|---|
| Auxiliary Air Temp. Door | The scan tool displays On or Off selections. This function drives the actuator to its minimum or maximum positions. |
| Auxiliary Mode Door | The scan tool displays On or Off selections. This function drives the actuator to its minimum or maximum positions. |
| Blower Motor | The scan tool displays Off or On selections. This function allows you to command the blower motor to its maximum (100%) or minimum (0%) speeds for 5 seconds. |
| Driver Temp. Door | The scan tool displays On or Off selections. The selection drives the actuator to its minimum (cold) or maximum (hot) positions for 20 seconds. |
| Inside Air Temp. Sensor Fan | The scan tool displays Commanded State: On or Off. This function allows you to command the inside air temperature sensors fan On and Off. |
| Mode Door Position | The scan tool displays On or Off selections. This function drives the actuator to its minimum (defrost) or maximum (upper) positions for 20 seconds. |
| Passenger Temp. Door | The scan tool displays On or Off selections. The selection drives the actuator to its minimum (hot) or maximum (cold) positions for 20 seconds. |
| Rear Defog Request | The scan tool displays Commanded State: On or Off. This function allows you to command the rear defog On and Off. |
| Recirculation Door | The scan tool displays On or Off selections. This function drives the actuator to its minimum (outside air) or maximum (recirculate) stops for 20 seconds. |
| Segment Check | The scan tool displays Commanded State: On or Off. This function allows you to illuminate all segments on the HVAC control modules display. |