Circuit/System Testing
NOTE:
All electrical components and accessories must be turned OFF and allowed to power down.
- Verify the integrity of the air induction system by inspecting for the following conditions:
- Any damaged components
- Loose or improper installation
- Improperly routed vacuum hoses
- Any vacuum leak
- Any type of restriction
- MAP sensor seal that is missing or damaged
- Verify that restrictions do not exist in the MAP sensor vacuum source.
- Verify that restrictions do not exist in the exhaust system. Refer to Restricted Exhaust .
- Ignition OFF, disconnect the MAP harness connector at the MAP sensor.
- Ignition OFF for 90 s, test for less than 5 Ω between the low reference circuit terminal A and ground.
- If greater than the specified value, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, test for 4.8-5.2 V between the 5 V reference circuit terminal C and ground.
- If less than the specified range, test the 5 V reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If greater than the specified range, test the 5 V reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Verify the scan tool MAP Sensor parameter is less than 12 kPa.
- If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Install a 3 A fused jumper wire between the signal circuit terminal B and the 5 V reference circuit terminal C. Verify the scan tool MAP Sensor parameter is greater than 103 kPa.
- If less than the specified range, test the signal circuit terminal B for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the MAP sensor.