Circuit/System Testing
IMPORTANT:
All electrical components and accessories must be turned OFF and allowed to power down.
- Ignition OFF, disconnect the MAP harness connector at the MAP sensor.
- Ignition OFF, test for less than 5 ohms between the low reference circuit and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit and ground.
- If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Verify the scan tool MAP Sensor parameter is less than 12 kPa.
- If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Install a 3A fused jumper wire between the signal circuit and the 5-volt reference circuit. Verify the scan tool MAP Sensor parameter is greater than 103 kPa.
- If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the MAP sensor.