Removal Procedure
Courtesy of GENERAL MOTORS COMPANY
- Using a scan tool, retrieve the percentage of remaining engine oil and automatic transaxle fluid life. Record the remaining engine oil and transaxle fluid life.
- Ensure that the ignition is in the OFF position.
- Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection
.
- Disconnect the engine harness electrical connector from the mass air flow/intake air temperature (MAF/IAT) sensor.
Courtesy of GENERAL MOTORS COMPANY
- Disconnect the positive crankcase ventilation (PCV) fresh air tube quick connect fitting from the air duct. Refer to Plastic Collar Quick Connect Fitting Service .
Courtesy of GENERAL MOTORS COMPANY
- Disconnect the secondary air injection (AIR) pump inlet tube quick connect fitting from the air cleaner upper housing. Refer to Plastic Collar Quick Connect Fitting Service .
Courtesy of GENERAL MOTORS COMPANY
- Loosen the air cleaner outlet duct clamp at the throttle body.
- Remove the air cleaner outlet duct from the throttle body.
Courtesy of GENERAL MOTORS COMPANY
- Disengage the lower housing clips (1).
- Disengage the upper housing front tabs from the lower housing.
- Remove the air cleaner upper housing.
Courtesy of GENERAL MOTORS COMPANY
- Disengage the engine harness electrical connector lever locks at the ECM.
- Remove the engine harness electrical connectors from the ECM.
- Remove the ECM from the air cleaner lower housing.