Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the interior liftgate control switch.
- Test for less than 10 Ω between the ground circuit terminal C and ground.
- If greater than the specified range, test the ground circuit for a open/high resistance.
- Ignition ON, verify the scan tool LGM Disable Switch parameter is Inactive.
- If not the specified value, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the liftgate control module.
- Install a 3 A fused jumper wire between the signal circuit terminal A and ground. Verify the scan tool LGM Disable Switch parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the liftgate control module.
- Verify the scan tool LGM Front Control Switch parameter is Inactive.
- If not the specified value, test the signal circuit terminal D for a short to ground. If the circuit tests normal, replace the liftgate control module.
- Install a 3 A fused jumper wire between the signal circuit terminal D and ground. Verify the scan tool LGM Front Control Switch parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the liftgate control module.
- If all circuits test normal, test or replace the interior liftgate control switch.