Circuit/System Testing
- Verify that a test lamp illuminates between the B+ circuit ring terminal 1 X2 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Ignition OFF, disconnect the X1 harness connector at the generator.
- Ignition ON, verify the scan tool ECM GEN-F Terminal Signal parameter is less than 5 percent.
- If greater than the specified range, test the field duty cycle circuit terminal 2 X1 for a short to voltage. If the circuit tests normal, replace the ECM.
- Install a 3A fused jumper wire between the field duty cycle circuit terminal 2 X1 and B+. Verify the scan tool ECM GEN-F Terminal Signal parameter is greater than 95 percent.
- If less than the specified range, test the circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the generator.