LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2012 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 5 (Hybrid/EV Control System) >> Diagnostic Information and Procedures >> DTC P0562 >> Circuit/System Testing
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Circuit/System Testing

WARNING: This page is about a different variant/trim than selected.
  1. Ignition OFF, remove the F103 drive motor generator control module sight shield. Refer to Drive Motor Generator Control Module Sight Shield Replacement , and disconnect the X4 harness connector at the K1 Accessory DC Power Control Module.
  2. Test for less than 1 ohm between the ground circuit terminal X4 bare ground strap and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Disconnect the X1 connector of the T6 drive motor generator control module. Ignition ON, verify that a test lamp illuminates between the control module voltage circuit terminals listed below and ground:
    • Terminal 6
    • Terminal 7
    • If the test lamp does not illuminate, test the control module voltage circuit for a short to ground or an open/high resistance.
  4. Ignition ON, verify that a test lamp illuminates between the control module voltage circuit terminal 20 and ground.
    • If the test lamp does not illuminate, test the control module voltage circuit for a short to ground or an open/high resistance.
  5. If all circuits test normal, replace the T6 drive motor generator power inverter module.