Circuit Short to Ground Open/High Resistance Short to Voltage Signal Performance
Low Speed GMLAN Serial Data 1 21 1 -
Ground (DLC, Terminal 5) - 1 - -
1 An open between the data link connector (DLC) and JX 200 will only effect the communication with the scan tool. The vehicle modules will still communicate.
1. No communication on any low speed GMLAN module
2. No communication on a specific low speed GMLAN module