LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2012 >> Escalade EXT >> Repair and Diagnosis >> External Pages >> Different car >> Section 1220 (Hybrid Engine Control System) >> Diagnostic Information and Procedures >> Engine Does Not AutoStop >> Typical Scan Tool Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Scan Tool Data

WARNING: This page is about a different car, the 2008 GMC Yukon and 2008 Chevrolet Tahoe. However, it is still accessible from the selected car via links, so may be relevant.
Autostop Inhibit Reasons

Parameter Display Autostop Inhibit or Autostart Reason2
Autostart/stop Override Scan tool Output Control active
Aux. Trans. Pump
With ECM Ambient Air Temperature less than 10°C (50°F)1
DTC P0C2B or P2797 set
OR
ECM Ambient Air Temperature less than 10°C (50°F)1
Aux. Trans. Pump
With ECM Ambient Air Temperature 10°C (50°F) - 15°C (59°F)1
DTC P0C2B or P2797 set
OR
TFT less than 35°C (95°F) or greater than 95°C (203°F)
Aux. Trans. Pump
With ECM Ambient Air Temperature 15°C (59°F) - 20° (68°F)1
DTC P0C2B or P2797 set
OR
TFT less than 25°C (77°F) or greater than 95°C (203°F)
Aux. Trans. Pump
With ECM Ambient Air Temperature greater than 20° (68°F)1
DTC P0C2B or P2797 set
TFT less than 20°C (68°F) or greater than 95°C (203°F)
Drvr Axle Torque Request Depression of the accelerator pedal has exceeded the torque capability for electric-only or EV Mode propulsion
ECM Request ECM DTC testing in progress or ECM DTCs present
ECT - High Limit ECT 110°C (230°F) or greater
2 Autostop if cools down to 90°C (194°F) once high temperature limit has been reached.
ECT - Low Limit
With ECM Ambient Air Temperature 10°C (50°F) - 20°C (68°F)1
ECT less than 68°C (154°F)
2 Autostart if cools down to 60°C (140°F) once high temperature limit has been reached
ECT - Low Limit
With ECM Ambient Air Temperature greater than 20°C (68°F)1
ECT less than 49°C (120°F)
2 Autostart if cools down to 44°C (111°F)
Hood Position Open or faulted
Hybrid Batt. Pack Voltage 250V or less
2 When Autostop limit has been achieved, Autostart if voltage drops to 200V
Hybrid Batt. Pack Power 15kW or less
Power is dependent upon battery temperature. Observe Hybrid Battery Temperature parameters when Hybrid Batt. Pack Power inhibits Autostop.
2 When Autostop limit has been achieved, Autostart if power drops to 12kW
Hybrid Battery SOC 50% or less
2 When Autostop limit has been achieved, Autostart if SOC drops to 46%
ICE Run Time
With ECM Ambient Air Temperature 10°C (50°F) - 15°C (59°F)1
Less than 20 seconds since ignition crank
ICE Run Time
With ECM Ambient Air Temperature greater than 15°C (59°F)1
Less than 5 seconds since ignition crank
Ignition Crank Ignition key not in RUN - engine remote started
IMS Range Gear Selector in Reverse or Manual
Inverter Temperature Greater than 65°C (149°F)
2 When Autostop limit has been achieved, Autostart at 70°C (158°F)
Min. Hybrid Batt. Module Voltage The minimum hybrid battery module pair voltage is less than 14 volts.
2 When Autostop limit has been achieved, Autostart if voltage drops to 12V.
Motor Temperature Greater than 165°C (329°F)
2 When Autostop limit has been achieved, Autostart at 170°C (338°F)
Run/Crank Mode SDGM Power mode is not in RUN
1 The HPCM monitors the ECM Ambient Air Temperature parameter to determine outside temperature. the ECM will default to 0°C (32°F) ambient air temperature if an IAT sensor DTC is present.
Hybrid Battery Temperature

Parameter Display Autostop Inhibit or Autostart Reason2
Hybrid Batt Min Cell Temp Less than 10°C (50°F)
Hybrid Batt Max Cell Temp Greater than 47°C (116°F)