LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2012 >> Escalade EXT >> Repair and Diagnosis >> External Pages >> Different car >> Section 1901 (Hybrid/EV Cooling System) >> Repair Instructions >> Generator Control Module Coolant Pump Replacement (Left)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Generator Control Module Coolant Pump Replacement (Left)

WARNING: This page is about a different car, the 2012 GMC Yukon, 2012 Chevrolet Tahoe, and 2012 Cadillac Escalade. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying Generator Control Module Left Coolant Pump
GM1966995Courtesy of GENERAL MOTORS COMPANY
Generator Control Module Coolant Pump Replacement (Left)

Callout Component Name

Preliminary Procedures

  1. Drain the cooling system. Refer to Generator Control Module Cooling System Draining and Filling .
  2. Raise the vehicle. Refer to Lifting and Jacking the Vehicle .
  3. Remove the engine shield. Refer to Engine Shield Replacement .
  4. Remove the generator control module coolant pump hose (pump to pump) Refer to Generator Control Module Coolant Pump Hose Replacement (Pump to Radiator) , Generator Control Module Coolant Pump Hose Replacement (Pump to Pump) .
  5. Remove the generator control module coolant pump hose (pump to radiator) Refer to Generator Control Module Coolant Pump Hose Replacement (Pump to Radiator) , Generator Control Module Coolant Pump Hose Replacement (Pump to Pump) .
1 Generator Control Module Coolant Pump Bolt (Qty: 2)
CAUTION:

Refer to Fastener Caution .


Tighten 
9 N.m (80 lb in)
2 Generator Control Module Coolant Pump
TIP:  Disconnect electrical connector.