Scan Tool Data List
WARNING: This page is about a different car, the 2007 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Engine Control Module (ECM) Hybrid
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Ignition ON/Engine OFF/Hood Open | |||
| 12V Battery Current | Engine Control Module, Data Display, Hybrid Data, Data Display | Amps | 0 amps |
| 12V Batt. Est. Temp. | Engine Control Module, Data Display, Hybrid Data, Data Display | Celsius/Fahrenheit | 82 degrees F |
| APM Control Mode | Engine Control Module, Data Display, Hybrid Data, Data Display | Off, High to Low, Low to High, Not Used | Off |
| APM Control Status | Engine Control Module, Data Display, Hybrid Data, Data Display | Charging, Current Limited, Shutdown, Not Used | Normal Change |
| APM Desired Voltage | Engine Control Module, Data Display, Hybrid Data, Data Display | Volts | 14 volts |
| APM Voltage | Engine Control Module, Data Display, Hybrid Data, Data Display | Volts | 12 volts |
| Aux. Trans Fluid Pump Command | Engine Control Module, Data Display, Hybrid Data, Data Display | Percent | 0 percent |
| Aux Trans Fluid Pump Relay | Engine Control Module, Data Display, Hybrid Data, Data Display | On/Off | On |
| Contactor Open Reason | Engine Control Module, Data Display, Hybrid Data, Data Display | None, SDM Command, Service Discon., ECM Discon., Hybrid Batt Tem, Fault | None |
| Desired Hybrid Batt. SOC | Engine Control Module, Data Display, Hybrid Data, Data Display | Percent | 69 percent |
| Desired Starter Gen Torque | Engine Control Module, Data Display, Hybrid Data, Data Display | N.m | 12 N.m |
| ECM Desired Contactor Position | Engine Control Module, Data Display, Hybrid Data, Data Display | Closed, Open | Closed |
| Economy Lamp Command | Engine Control Module, Data Display, Hybrid Data, Data Display | On/Off | Off |
| Eng Auto Start Reason | Engine Control Module, Data Display, Hybrid Data, Data Display | None, BPP, APP, Trans Range Tim, Auto Stop Time, Hybrid Batt Stat, Aux TFP Pump, Coast Speed Low, Coast Speed High, BBC Low, Coast Speed Inc, 12V Batt Hi Amp, 12V Batt Lo Amp, Fault, ECT Low, Device Control, A/C Request, ECT High, Engine Control | None |
| Hill Hold Lamp Command | Engine Control Module, Data Display, Hybrid Data, Data Display | On/Off | Off |
| Hood Switch Indicated Position | Engine Control Module, Data Display, Hybrid Data, Data Display | Closed/Ajar/Open | Open |
| Hybrid Batt Avg Cell Temp. | Engine Control Module, Data Display, Hybrid Data, Data Display | Celsius/Fahrenheit | 73 degrees F |
| Hybrid Batt Max Cell Temp. | Engine Control Module, Data Display, Hybrid Data, Data Display | Celsius/Fahrenheit | 75 degrees F |
| Hybrid Batt Min Cell Temp. | Engine Control Module, Data Display, Hybrid Data, Data Display | Celsius/Fahrenheit | 73 degrees F |
| Hybrid Batt Power Available | Engine Control Module, Data Display, Hybrid Data, Data Display | Watts | 13,616.0 watts |
| Hybrid Battery Current | Engine Control Module, Data Display, Hybrid Data, Data Display | Amps | 0.0 amps |
| Hybrid Battery Internal Resistance | Engine Control Module, Data Display, Hybrid Data, Data Display | Ohms | 0 ohms |
| Hybrid Battery SOC | Engine Control Module, Data Display, Hybrid Data, Data Display | Percent | 60 percent |
| Hybrid Battery Voltage | Engine Control Module, Data Display, Hybrid Data, Data Display | Volts | 39.67 volts |
| Hybrid Mode Status | Engine Control Module, Data Display, Hybrid Data, Data Display | Hybrid DFCO, Regen Braking, Auto Start, Auto Stop, Fault Active, Key Crank Required, Key Crank Active | Hybrid DFCO |
| Ignition 1 Signal | Engine Control Module, Data Display, Hybrid Data, Data Display | Volts | 12 volts |
| Last Start Method | Engine Control Module, Data Display, Hybrid Data, Data Display | Starter GEN, 12V Starter, Tandem Starter | 12V Starter |
| SGCM Coolant Pump Relay Command | Engine Control Module, Data Display, Hybrid Data, Data Display | Off/On | Off |
| SGCM Des. Contactor Position | Engine Control Module, Data Display, Hybrid Data, Data Display | Closed/Open | Closed |
| SGCM Temperature | Engine Control Module, Data Display, Hybrid Data, Data Display | Celsius/Fahrenheit | 75 degrees F |
| Starter Gen. Belt Slip | Engine Control Module, Data Display, Hybrid Data, Data Display | Percent | -100 percent |
| Starter Genenerator Calculated Torque | Engine Control Module, Data Display, Hybrid Data, Data Display | N.m | 8.9 N.m |
| Starter Generator Mode | Engine Control Module, Data Display, Hybrid Data, Data Display | Neutral, CKP Indexing, Key Crank Active, Auto Start, Transition, Charging, Discharging, Regen Braking, Accel Boost, Spin Dwn Control | Neutral |
| Starter Generator Speed | Engine Control Module, Data Display, Hybrid Data, Data Display | RPM | 0 RPM |
Starter/Generator Control Module (SGCM)
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Ignition ON/Engine OFF/Hood Open | |||
| 14 Volt Power Module Output Current | Starter/Generator Control Module, SGCM Data Display, Data Display | Amps | 0.0 amps |
| 14 Volt Power Module Output Voltage | Starter/Generator Control Module, SGCM Data Display, Data Display | Volts | 13.9 volts |
| 14 Volt Power Module Temperature | Starter/Generator Control Module, SGCM Data Display, Data Display | Degrees | 73 degrees F |
| APM Control Command Mode | Starter/Generator Control Module, SGCM Data Display, Data Display | Off, High to Low, Low to High, Not Used | Off |
| APM Control Status | Starter/Generator Control Module, SGCM Data Display, Data Display | Charging, Current Limited, Shutdown, Not Used | Charging |
| APM Desired Voltage | Starter/Generator Control Module, SGCM Data Display, Data Display | Volts | 12.07 volts |
| Aux Trans Fluid Pump Relay | Starter/Generator Control Module, SGCM Data Display, Data Display | On/Off | On |
| Engine Speed | Starter/Generator Control Module, SGCM Data Display, Data Display | RPM | 0 RPM |
| Hood Ajar Switch 1 | Starter/Generator Control Module, SGCM Data Display, Data Display | Open/Closed | Closed |
| Hood Ajar Switch 2 | Starter/Generator Control Module, SGCM Data Display, Data Display | Open/Closed | Open |
| Hood Position | Starter/Generator Control Module, SGCM Data Display, Data Display | Open, Closed | Closed |
| Hybrid System Voltage | Starter/Generator Control Module, SGCM Data Display, Data Display | Volts | 39.7 volts |
| Starter/Generator Control Module Motor Electronics Temperature | Starter/Generator Control Module, SGCM Data Display, Data Display | Degrees | 84 degrees F |
| Starter/Generator Inverter Temperature | Starter/Generator Control Module, SGCM Data Display, Data Display | Celcius/Farenheit | 75 degrees F |
| Starter/Generator Temperature | Starter/Generator Control Module, SGCM Data Display, Data Display | Celcius/Farenheit | 77 degrees F |
| Starter Generator Field Circuit | Starter/Generator Control Module, SGCM Data Display, Data Display | Disable, Enable | Enable |
| Starter Generator Field Current | Starter/Generator Control Module, SGCM Data Display, Data Display | Amps | 0.0 amps |
| Starter Generator Position | Starter/Generator Control Module, SGCM Data Display, Data Display | Degrees | 16 degrees |
| Starter Generator Speed | Starter/Generator Control Module, SGCM Data Display, Data Display | RPM | 0 RPM |
| Starter Generator Speed Commanded | Starter/Generator Control Module, SGCM Data Display, Data Display | RPM | 0 RPM |
Battery Energy Control Module (BECM)
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Ignition ON/Engine OFF/Hood Open | |||
| 14 Volt Power Module Output Voltage | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 11.7 volts |
| Hybrid Batery High Current Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 3.3 volts |
| Hybrid Battery High Current Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Amps | 0.0 amps |
| Hybrid Battery Low Current Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 2.5 volts |
| Hybrid Battery Low Current Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Amps | 0.0 amps |
| Hybrid Battery 1 Temperature | Battery Energy Control Module, BECM Data Display, Data Display | Celsius/Fahrenheit | 75 degrees F |
| Hybrid Battery 2 Temperature | Battery Energy Control Module, BECM Data Display, Data Display | Celsius/Fahrenheit | 75 degrees F |
| Hybrid Battery 3 Temperature | Battery Energy Control Module, BECM Data Display, Data Display | Celsius/Fahrenheit | 75 degrees F |
| Hybrid Battery 4 Temperature | Battery Energy Control Module, BECM Data Display, Data Display | Celsius/Fahrenheit | 75 degrees F |
| Hybrid Battery 5 Temperature | Battery Energy Control Module, BECM Data Display, Data Display | Celsius/Fahrenheit | 75 degrees F |
| Hybrid Battery 6 Temperature | Battery Energy Control Module, BECM Data Display, Data Display | Celsius/Fahrenheit | 75 degrees F |
| Hybrid Battery 1 Temperature Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 1.9 volts |
| Hybrid Battery 2 Temperature Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 1.9 volts |
| Hybrid Battery 3 Temperature Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 1.9 volts |
| Hybrid Battery 4 Temperature Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 1.9 volts |
| Hybrid Battery 5 Temperature Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 1.9 volts |
| Hybrid Battery 6 Temperature Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 1.9 volts |
| Hybrid Battery Circuit 1 | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 13.2 volts |
| Hybrid Battery Circuit 2 | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 13.2 volts |
| Hybrid Battery Circuit 3 | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 13.2 volts |
| Hybrid Battery Current Sensor Performance | Battery Energy Control Module, BECM Data Display, Data Display | Zero Range, DC/AC Polarity, High/Low Sensor | Zero Range |
| Hybrid Battery Fan Commanded | Battery Energy Control Module, BECM Data Display, Data Display | Percent | 0 percent |
| Hybrid Battery Pack Cooling Fan | Battery Energy Control Module, BECM Data Display, Data Display | RPM | 0 RPM |
| Hybrid Battery Positive Contactor Status | Battery Energy Control Module, BECM Data Display, Data Display | Closed, Open Impact DTC, Open Service Dis, ECM Fault, Overtemp, Fault | Closed |
| Hybrid Battery Sensor | Battery Energy Control Module, BECM Data Display, Data Display | Amps | 0.0 amps |
| Hybrid Battery System Voltage | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 39.6 volts |
| Hybrid System Voltage | Battery Energy Control Module, BECM Data Display, Data Display | Volts | 39.9 volts |