Scan Tool Data Definitions
- 8-Digit GM Part Number
-
The scan tool displays the part number of the module.
- Battery Voltage
-
The scan tool displays 0-16 volts. The level of battery voltage at the module.
- Calibration ID
-
The scan tool displays a 4-digit number. This number designates the calibration or program level used in the PROM.
- Current
-
The scan tool displays 0-127.5 amps. The current measured during seat operation.
- Front Vertical Sensor
-
The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the seat front vertical position. High scan tool values (volts or A/D) indicate that the seat front is in the up position and low values indicate that the seat front is in the down position.
- Hardware Level
-
The scan tool displays a 4-digit number representing the level of hardware incorporated into the module.
- Horizontal Sensor
-
The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the seat horizontal position. High scan tool values (volts or A/D) indicate that the seat is in the forward position and low values indicate that the seat is in the rearward position.
- Julian Date of Build
-
The scan tool displays a 3-digit number. This number is the day of the year that the module was built.
- Lumbar Horizontal Sensor
-
The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the lumbar horizontal position. High scan tool values (volts or A/D) indicate that the Lumbar is in the forward position and low values indicate that the lumbar is in the rearward position.
- Lumbar Vertical Sensor
-
The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the lumbar vertical position. High scan tool values (volts or A/D) indicate that the lumbar is in the up position and low values indicate that the lumbar is in the down position.
- Memory Recall Switches
-
The scan tool displays 0.43-2.74 volts. When the memory 1 switch is pressed, the scan tool will momentarily display 2.74 volts, when the memory 2 switch is pressed, 1.78 volts is displayed, and when the EXIT switch is pressed, 0.96 volts is displayed.
- PROM ID
-
The scan tool displays a 4-digit number. This is the identification number of the PROM that is incorporated into the module.
- Rear Vertical Sensor
-
The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the seat rear vertical position. High scan tool values (volts or A/D) indicate that the seat rear vertical is in the up position and low values indicate that the seat rear vertical is in the down position.
- Recline Sensor
-
The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the seat recline position. High scan tool values (volts or A/D) indicate that the seat recline is in the froward position and low values indicate that the seat recline is in the rearward position.
- Seat Forward - Input
-
The scan tool displays Inactive/Active. When the seat forward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Forward - Output
-
The scan tool displays Inactive/Active. When the seat forward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat horizontal motor in the forward direction.
- Seat Front Down - Input
-
The scan tool displays Inactive/Active. When the seat front down switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Front Down - Output
-
The scan tool displays Inactive/Active. When the seat front down switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat front vertical motor in the down direction.
- Seat Front Up - Input
-
The scan tool displays Inactive/Active. When the seat front up switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Front Up - Output
-
The scan tool displays Inactive/Active. When the seat front up switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat front vertical motor in the up direction.
- Seat Lumbar Down - Input
-
The scan tool displays Inactive/Active. When the seat lumbar down switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Lumbar Down - Output
-
The scan tool displays Inactive/Active. When the seat lumbar down switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the lumbar vertical motor in the down direction.
- Seat Lumbar Forward - Input
-
The scan tool displays Inactive/Active. When the seat lumbar forward switch is activated, the scan tool will momentarily display switch input to the memory seat module as Active.
- Seat Lumbar Forward - Output
-
The scan tool displays Inactive/Active. When the seat lumbar forward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the lumbar horizontal motor in the forward direction.
- Seat Lumbar Rearward - Input
-
The scan tool displays Inactive/Active. When the seat lumbar rearward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Lumbar Rearward - Output
-
The scan tool displays Inactive/Active. When the seat lumbar rearward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the lumbar horizontal motor in the rearward direction.
- Seat Lumbar Up - Input
-
The scan tool displays Inactive/Active. When the seat lumbar up switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Lumbar Up - Output
-
The scan tool displays Inactive/Active. When the seat lumbar up switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory module is commanding the lumbar vertical motor the up direction.
- Seat Rear Down - Input
-
The scan tool displays Inactive/Active. When the seat rear down switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Rear Down - Output
-
The scan tool displays Inactive/Active. When the seat rear down switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat rear vertical motor in the down direction.
- Seat Rear Up - Input
-
The scan tool displays Inactive/Active. When the seat rear up switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Rear Up - Output
-
The scan tool displays Inactive/Active. When the seat rear up switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat rear vertical motor in the up direction.
- Seat Rearward - Input
-
The scan tool displays Inactive/Active. When the seat rearward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Rearward - Output
-
The scan tool displays Inactive/Active. When the seat rearward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat horizontal motor in the rearward direction.
- Seat Recline Forward - Input
-
The scan tool displays Inactive/Active. When the seat recline forward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Recline Forward - Output
-
The scan tool displays Inactive/Active. When the seat recline forward switch is activated or a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat recline motor in the forward direction.
- Seat Recline Rearward - Input
-
The scan tool displays Inactive/Active. When the seat recline rearward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.
- Seat Recline Rearward - Output
-
The scan tool displays Inactive/Active. When the seat recline rearward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat recline motor in the rearward direction.
- Software Level
-
The scan tool displays the 4-digit number of the software incorporated into the module.
- Year Module Built
-
The scan tool displays a 4-digit number. This number represents the year the module was built.