8-Digit GM Part Number

The scan tool displays the part number of the module.

Battery Voltage

The scan tool displays 0-16 volts. The level of battery voltage at the module.

Calibration ID

The scan tool displays a 4-digit number. This number designates the calibration or program level used in the PROM.

Current

The scan tool displays 0-127.5 amps. The current measured during seat operation.

Front Vertical Sensor

The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the seat front vertical position. High scan tool values (volts or A/D) indicate that the seat front is in the up position and low values indicate that the seat front is in the down position.

Hardware Level

The scan tool displays a 4-digit number representing the level of hardware incorporated into the module.

Horizontal Sensor

The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the seat horizontal position. High scan tool values (volts or A/D) indicate that the seat is in the forward position and low values indicate that the seat is in the rearward position.

Julian Date of Build

The scan tool displays a 3-digit number. This number is the day of the year that the module was built.

Lumbar Horizontal Sensor

The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the lumbar horizontal position. High scan tool values (volts or A/D) indicate that the Lumbar is in the forward position and low values indicate that the lumbar is in the rearward position.

Lumbar Vertical Sensor

The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the lumbar vertical position. High scan tool values (volts or A/D) indicate that the lumbar is in the up position and low values indicate that the lumbar is in the down position.

Memory Recall Switches

The scan tool displays 0.43-2.74 volts. When the memory 1 switch is pressed, the scan tool will momentarily display 2.74 volts, when the memory 2 switch is pressed, 1.78 volts is displayed, and when the EXIT switch is pressed, 0.96 volts is displayed.

PROM ID

The scan tool displays a 4-digit number. This is the identification number of the PROM that is incorporated into the module.

Rear Vertical Sensor

The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the seat rear vertical position. High scan tool values (volts or A/D) indicate that the seat rear vertical is in the up position and low values indicate that the seat rear vertical is in the down position.

Recline Sensor

The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the seat recline position. High scan tool values (volts or A/D) indicate that the seat recline is in the froward position and low values indicate that the seat recline is in the rearward position.

Seat Forward - Input

The scan tool displays Inactive/Active. When the seat forward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Forward - Output

The scan tool displays Inactive/Active. When the seat forward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat horizontal motor in the forward direction.

Seat Front Down - Input

The scan tool displays Inactive/Active. When the seat front down switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Front Down - Output

The scan tool displays Inactive/Active. When the seat front down switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat front vertical motor in the down direction.

Seat Front Up - Input

The scan tool displays Inactive/Active. When the seat front up switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Front Up - Output

The scan tool displays Inactive/Active. When the seat front up switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat front vertical motor in the up direction.

Seat Lumbar Down - Input

The scan tool displays Inactive/Active. When the seat lumbar down switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Lumbar Down - Output

The scan tool displays Inactive/Active. When the seat lumbar down switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the lumbar vertical motor in the down direction.

Seat Lumbar Forward - Input

The scan tool displays Inactive/Active. When the seat lumbar forward switch is activated, the scan tool will momentarily display switch input to the memory seat module as Active.

Seat Lumbar Forward - Output

The scan tool displays Inactive/Active. When the seat lumbar forward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the lumbar horizontal motor in the forward direction.

Seat Lumbar Rearward - Input

The scan tool displays Inactive/Active. When the seat lumbar rearward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Lumbar Rearward - Output

The scan tool displays Inactive/Active. When the seat lumbar rearward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the lumbar horizontal motor in the rearward direction.

Seat Lumbar Up - Input

The scan tool displays Inactive/Active. When the seat lumbar up switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Lumbar Up - Output

The scan tool displays Inactive/Active. When the seat lumbar up switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory module is commanding the lumbar vertical motor the up direction.

Seat Rear Down - Input

The scan tool displays Inactive/Active. When the seat rear down switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Rear Down - Output

The scan tool displays Inactive/Active. When the seat rear down switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat rear vertical motor in the down direction.

Seat Rear Up - Input

The scan tool displays Inactive/Active. When the seat rear up switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Rear Up - Output

The scan tool displays Inactive/Active. When the seat rear up switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat rear vertical motor in the up direction.

Seat Rearward - Input

The scan tool displays Inactive/Active. When the seat rearward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Rearward - Output

The scan tool displays Inactive/Active. When the seat rearward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat horizontal motor in the rearward direction.

Seat Recline Forward - Input

The scan tool displays Inactive/Active. When the seat recline forward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Recline Forward - Output

The scan tool displays Inactive/Active. When the seat recline forward switch is activated or a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat recline motor in the forward direction.

Seat Recline Rearward - Input

The scan tool displays Inactive/Active. When the seat recline rearward switch is activated, the scan tool will momentarily display the switch input to the memory seat module as Active.

Seat Recline Rearward - Output

The scan tool displays Inactive/Active. When the seat recline rearward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the memory seat module is commanding the seat recline motor in the rearward direction.

Software Level

The scan tool displays the 4-digit number of the software incorporated into the module.

Year Module Built

The scan tool displays a 4-digit number. This number represents the year the module was built.