LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2014 >> ELR >> Repair and Diagnosis >> Electrical >> Charging Systems >> Battery, Charging System And Starting System >> Repair Instructions >> Battery Positive and Negative Cable Replacement (APM Module Ground Cable)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Battery Positive and Negative Cable Replacement (APM Module Ground Cable)

Fig 1: Battery Positive and Negative Cables (APM Module Ground Cable)
GM2359321Courtesy of GENERAL MOTORS COMPANY
Battery Positive and Negative Cable Replacement (APM Module Ground Cable)

Callout Component Name
WARNING:

Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure will perform the following tasks:

  • Identify how to disable high voltage.
  • Identify how to test for the presence of high voltage.
  • Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.

Failure to follow the procedures exactly as written may result in serious injury or death.

Preliminary Procedures

  1. Disable the high voltage. Refer to High Voltage Disabling
  2. Remove the rear compartment floor stowage trim compartment. Refer to Rear Compartment Floor Stowage Trim Compartment Replacement
  3. Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .
1 Accessory DC Power Control Module Nut
CAUTION:

Refer to Fastener Caution .


Tighten 
22 N.m (16 lb ft)
2 Accessory DC Power Control Module Bracket Nut
Tighten 
22 N.m (16 lb ft)
3 Battery Negative Cable
Procedure 
After replacing the APM module ground cable, enable the high voltage system. Refer to High Voltage Enabling .