Circuit/System Testing
- Ignition OFF, disconnect the X2 harness connector at the K39 liftgate control module.
- Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 3 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Ignition OFF, connect the X2 harness connector and disconnect the X3 harness connector at the K39 liftgate control module.
- Test for infinite resistance between the control circuit terminal 1 and ground.
- If not the specified value, replace the liftgate actuator assembly.
- Test for infinite resistance between the control circuit terminal 2 and ground.
- If not the specified value, replace the liftgate actuator assembly.
- Test for less than 25 Ω between the control circuit terminal 1 and the control circuit terminal 2.
- If greater than the specified range, replace the liftgate actuator assembly.
- If all circuits test normal, replace the K39 liftgate control module.