Installation Procedure
- Multifunction Energy Storage Capacitor Control Module (2)» Install
Courtesy of GENERAL MOTORS COMPANY
- Multifunction Energy Storage Capacitor Control Module Nut (1)» Install and tighten Install and tighten 9 N.m (80 lb in) [2x]
- Auxiliary Generator Battery Jumper Cable (2)» Install [3x]
Courtesy of GENERAL MOTORS COMPANY
- Auxiliary Generator Battery Jumper Cable Nut (1)» Install and tighten 12 N.m (106 lb in) [3x]
- Connect the electrical connectors. (3)
- Multifunction Energy Storage Capacitor Control Module Bracket (2)» Install
Courtesy of GENERAL MOTORS COMPANY
- Multifunction Energy Storage Capacitor Control Module Bracket Bolt (1) Install and tighten 9 N.m (80 lb in) [2x]
- Multifunction Energy Storage Capacitor Control Module Bracket Bolt (3) Install and tighten [2x] 9 N.m (80 lb in)
- {If equipped} Active Safety Control Module Bracket (2)» Install
Courtesy of GENERAL MOTORS COMPANY
- {If equipped} Active Safety Control Module Bracket Bolt (1)» Install and tighten 2.5 N.m (22 lb in)
- Rear Compartment Side Trim Replacement - Left Side
» Install
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
- Perform Stop/Start Capacitor Control State Health Reset. Refer to Stop/Start Capacitor Control State of Health Reset