Stop/Start Capacitor Control Module Malfunction
- Ignition OFF, disconnect the C1 Battery (disconnect negative cable of the battery).
- Disconnect the X5 harness connector at the K176 Stop/Start Capacitor Control Module.
- Test for less than 10 Ω between the ground circuit terminal A and ground.
- Ignition OFF.
- Test for less than 2 Ω in the ground circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, repair the open/high resistance in the ground connection.
- Reconnect the X5 harness connector at the K176 Stop/Start Capacitor Control Module.
- Reconnect the C1 Battery.
- Disconnect the X2 harness connector at the K176 Stop/Start Capacitor Control Module
- Verify a test lamp illuminates between the B+ circuit terminal 1 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2 Ω in the B+ circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the B+ circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K176 Stop/Start Capacitor Control Module.
- If the test lamp illuminates
- Verify a test lamp illuminates between the B+ circuit terminal 7 X1 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2 Ω in the B+ circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the B+ circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K176 Stop/Start Capacitor Control Module.
- If the test lamp illuminates
- Verify a test lamp illuminates between the B+ circuit terminal 6 X1 and ground.
- If the test lamp does not illuminate and the circuit fuse is good
- Ignition OFF, remove the test lamp.
- Test for less than 2 Ω in the B+ circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
- If the test lamp does not illuminate and the circuit fuse is open
- Ignition OFF, remove the test lamp.
- Test for infinite resistance between the B+ circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K176 Stop/Start Capacitor Control Module.
- If the test lamp illuminates
- Replace the K176 Stop/Start Capacitor Control Module.