K33 HVAC Control Module X3
|
|
Connector Part Information
- Harness Type: HVAC
- OEM Connector: 15126711
- Service Connector: 15126711
- Description: 20-Way F 0.64 Series (BK with WH Terminal Position Assurance)
|
Terminal Part Information
| Terminal Type ID |
Terminated Lead |
Diagnostic Test Probe |
Terminal Removal Tool |
Service Terminal |
Tray |
Core Crimp |
Insulation Crimp |
| I |
Not Available |
Not Available |
Not Available |
Not Available |
Not Available |
Not Available |
Not Available |
| Pin |
Size |
Color |
Circuit |
Function |
Terminal Type ID |
Option |
| 1 |
0.35 |
GN |
516 |
Upper Left Air Temperature Sensor Signal |
I |
- |
| 2 |
0.5 |
PK |
119 |
Mode Door Control |
I |
- |
| 3 |
0.5 |
GY/RD |
2273 |
Mode Door Control |
I |
- |
| 4 |
0.35 |
WH |
2275 |
Mode 1 Valve Position Sensor Signal |
I |
- |
| 5-8 |
- |
- |
- |
Not Occupied |
- |
- |
| 9 |
0.35 |
BK/YE |
1791 |
Air Temperature Door Control Low Reference |
I |
- |
| 10 |
- |
- |
- |
Not Occupied |
- |
- |
| 11 |
0.5 |
YE/WH |
1199 |
Air Temperature Door Control |
I |
- |
| 12 |
0.5 |
BN/BK |
2210 |
Air Temperature Door Control |
I |
- |
| 13 |
0.35 |
GY/YE |
733 |
Air Temperature Door Position Signal |
I |
- |
| 14-15 |
- |
- |
- |
Not Occupied |
- |
- |
| 16 |
0.5 |
L-BU |
1614 |
Recirculation Door Control |
I |
- |
| 17 |
0.5 |
D-BU |
2274 |
Recirculation Door Control |
I |
- |
| 18 |
0.35 |
D-BU |
1838 |
Recirculation Door Position Signal |
I |
- |
| 19 |
- |
- |
- |
Not Occupied |
- |
- |
| 20 |
0.35 |
GN/RD |
6137 |
EVAP Core Temperature Sensor Signal |
I |
- |