K84 Keyless Entry Control Module X4
|
|
Connector Part Information
- Harness Type: Body
- OEM Connector: 31410-1201
- Service Connector: 15126710
- Description: 20-Way F 64 Series, Sealed (GY)
|
Terminal Part Information
| Terminal Type ID |
Terminated Lead |
Diagnostic Test Probe |
Terminal Removal Tool |
Service Terminal |
Tray Name |
Core Crimp |
Insulation Crimp |
| I |
13575867 |
J-35616-64B (LT BU) |
J-38125-215A |
SAIT-A03T-M064 |
Yazaki 14 |
P |
P |
| Pin |
Size |
Color |
Circuit |
Function |
Terminal Type ID |
Option |
| 1 - 2 |
- |
- |
- |
Not Occupied |
- |
- |
| 3 |
0.35 |
WH/BN |
3572 |
Driver Door Unlatch Enable Signal |
I |
- |
| 4 - 5 |
- |
- |
- |
Not Occupied |
- |
- |
| 6 |
0.5 |
VT/GY |
218 |
Keyless Entry Antenna Signal 1 |
I |
- |
| 7 |
0.5 |
BK/BN |
219 |
Keyless Entry Antenna Low Reference 1 |
I |
- |
| 8 |
- |
- |
- |
Not Occupied |
- |
- |
| 9 |
0.5 |
BK/L-GN |
5711 |
Keyless Entry Antenna Low Reference 2 |
I |
- |
| 10 |
- |
- |
- |
Not Occupied |
- |
- |
| 11 |
0.35 |
VT/WH |
3571 |
Passenger Door Handle Switch Signal |
I |
- |
| 12 |
0.35 |
L-GN/WH |
3570 |
Driver Door Handle Switch Signal |
I |
- |
| 13 |
- |
- |
- |
Not Occupied |
- |
- |
| 14 |
0.35 |
L-BU |
3573 |
Non Driver Door Unlatch Enable Signal |
I |
- |
| 15 |
- |
- |
- |
Not Occupied |
- |
- |
| 16 |
0.5 |
YE/L-BU |
5710 |
Keyless Entry Antenna Signal 5 |
I |
- |
| 17 |
- |
- |
- |
Not Occupied |
- |
- |
| 18 |
0.5 |
BK/YE |
5714 |
Keyless Entry Antenna Low Reference 5 |
I |
- |
| 19 |
- |
- |
- |
Not Occupied |
- |
- |
| 20 |
0.5 |
L-GN |
5707 |
Keyless Entry Antenna Signal 2 |
I |
- |