Circuit/System Testing
- Ignition OFF and all vehicle systems OFF, disconnect the X3 harness connector at the K39 Liftgate Control Module. It may take up to 2 minutes for all vehicle systems to power down.
- Test for less than 20 Ω between terminal 11 at the K39 Liftgate Control Module and ground.
- If 20 Ω or greater
- Replace the K39 Liftgate Control Module
- If less than 20 Ω
- Ignition ON
- Verify a test lamp illuminates between terminal 8 at the K39 Liftgate Control Module and ground.
- If the test lamp does not illuminate
Replace the K39 Liftgate Control Module
- If the test lamp illuminates
- If the test lamp does not illuminate
- Test for greater than 11 V between terminal 9 at the K39 Liftgate Control Module and ground.
- If 11 V or less
Replace the K39 Liftgate Control Module
- If greater than 11 V
- If 11 V or less
- Test for greater than 11 V between terminal 10 at the K39 Liftgate Control Module and ground.
- If 11 V or less
Replace the K39 Liftgate Control Module
- If greater than 11 V
Replace the M17 Liftgate Motor Assembly.
- If 11 V or less