Circuit/System Testing
- Ignition/Vehicle & All vehicle systems» OffNOTE: It may take up to 2 min for all vehicle systems to power down before an accurate ground or low reference circuit continuity test can be performed.
- Disconnect the electrical connector: S46B Liftgate Unlatch Switch
- Test for less than 10 Ω between the test points: Low Reference circuit terminal 2 & Ground
- If 10 Ω or greater
- Disconnect the electrical connector: K39 Liftgate Control Module
- Test for less than 2 Ω between the test points: Low Reference circuit terminal 2 @ Component harness & Terminal 16 X1 @ Control module harness
- If 2 Ω or greater» Repair the open/high resistance in the circuit.
- If less than 2 Ω» Replace the component: K39 Liftgate Control Module
- If less than 10 Ω
- Ignition» On / Vehicle» In Service Mode
- Verify the scan tool parameter: Liftgate Handle Switch=Inactive
- If not the specified state
- Ignition/Vehicle» Off
- Disconnect the electrical connector: K39 Liftgate Control Module
- Test for infinite resistance between the test points: Signal circuit terminal 1 @ Component harness & Ground
- If less than infinite resistance» Repair the short to ground on the circuit.
- If infinite resistance» Replace the component: K39 Liftgate Control Module
- If the specified state
- Connect a 3 A fused jumper wire between the test points: Signal circuit terminal 1 & Low Reference circuit terminal 2
- Verify the scan tool parameter: Liftgate Handle Switch=Active
- If not the specified state
- Ignition/Vehicle» Off & Remove» Jumper wire(s)
- Disconnect the electrical connector:K39 Liftgate Control Module
- Ignition» On / Vehicle» In Service Mode
- Test for less than 1 V between the test points: Signal circuit terminal 1 @ Component harness & Ground
- If 1 V or greater» Repair the short to voltage on the circuit.
- If less than 1 V
- Ignition/Vehicle » Off
- Test for less than 2 Ω between the test points: Signal circuit terminal 1 @ Component harness & Terminal 14 X1 @ Control module harness
- If 2 Ω or greater» Repair the open/high resistance in the circuit.
- If less than 2 Ω» Replace the component: K39 Liftgate Control Module
- If the specified state
- Test or replace the component:S46B Liftgate Unlatch Switch