Installation Procedure

  1. Generator Control Module Coolant/Air Separator (1) @ Generator Control Module Coolant Radiator Bracket» Install
    Fig 1: Generator Control Module Coolant/Air Separator
    GM4485384Courtesy of GENERAL MOTORS COMPANY
  2. Generator Control Module Coolant/Air Separator Bolt (1) @ Generator Control Module Coolant/Air Separator» Install and tighten 9 N.m (80 lb in)
    Fig 2: Generator Control Module Coolant/Air Separator Bolt
    GM4485383Courtesy of GENERAL MOTORS COMPANY
    CAUTION: Refer to Fastener Caution .
  3. Drive Motor Generator Control Module Coolant Pump Hose (2) @ Generator Control Module Coolant/Air Separator» Install
    Fig 3: Retainer
    GM4485247Courtesy of GENERAL MOTORS COMPANY
  4. Retainer (1) @ Drive Motor Generator Control Module Coolant Pump Hose (2)» Engage
  5. Generator Control Module Coolant Tank Hose (2) @ Generator Control Module Coolant/Air Separator» Install
    Fig 4: Generator Control Module Coolant Tank Hose Clamp
    GM4485286Courtesy of GENERAL MOTORS COMPANY
  6. Generator Control Module Coolant Tank Hose Clamp (1)» Engage - Hose Clamp Replacement Guidelines - Spring Type
  7. Fill the power electronics and auxiliary radiator cooling system. Refer to Power Electronics and Auxiliary Radiator Drain and Fill (LTG HP9) 
  8. Enable the high voltage system. Refer to High Voltage Enabling
  9. Start the engine and check for coolant leaks.