T1 Accessory DC/AC Power Inverter Module
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | 13575838 | J-35616-35 (VT) | J-38125-11A | 7116-4110-02 | Yazaki 9 | E | C |
| II | 13575838 | J-35616-35 (VT) | J-38125-11A | 7116-4111-02 | Yazaki 9 | E | A |
| III | 13575839 | J-35616-35 (VT) | J-38125-11A | 7116-4112-02 | Yazaki 9 | C | D |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | - | - | - | Not Occupied | - | - |
| 2 | 0.75 | BK | 5683 | 120 V AC Phase A | II | KI6 |
| 3 | 0.75 | BN | 686 | 230 V AC Phase A | II | KI7 |
| 4 - 5 | - | - | - | Not Occupied | - | - |
| 6 | 2.5 2.5 |
RD/VT RD/VT |
4640 4640 |
Battery Positive Voltage Battery Positive Voltage |
III III |
KI6 KI7 |
| 7 | 0.75 0.75 |
RD BU |
5684 6865 |
120 V AC Phase B 230 V AC Phase B |
II II |
KI6 KI7 |
| 8 - 9 | - | - | - | Not Occupied | - | - |
| 10 | 0.5 0.5 |
BARE BARE |
514 514 |
Low Reference Low Reference |
I I |
KI6 KI7 |
| 11 | 2.5 2.5 |
BK BK |
2450 2450 |
Ground Ground |
III III |
KI6 KI7 |
| 12 | 0.35 0.35 |
BU/WH BU/WH |
6807 6807 |
DC To AC Inverter Control DC To AC Inverter Control |
I I |
KI6 KI7 |