Installation Procedure
- Clean the sealing surfaces of the EBCM and the BPMV with denatured alcohol and allow to dry.
- Inspect the EBCM to BPMV gasket for damage and replace, if necessary.
- Install the EBCM (1) to the BPMV.
- Install the EBCM bolts (1) and tighten in a cross pattern to 3 N.m (27 lb in).
- Connect the EBCM electrical connector.
- Program the EBCM. Refer to Control Module References .
CAUTION:
Refer to Fastener Caution .