Circuit/System Testing
- Ignition/Vehicle & All vehicle systems - Off
- Disconnect the electrical connector: X2 @X53A Fuse Block - Rear Body
- Test for less than 10 ohms between the test points:Ground circuit terminal 34 X2 & Ground
- If 10 ohms or greater
- Ground Connection - Disconnect
- Test for less than 2 ohms between the test points:Ground circuit terminal 34 X2 & Ground Connection
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Repair the open/high resistance in the ground connection.
- If less than 10 ohms
- Connect the electrical connector: X2 @X53A Fuse Block - Rear Body
- Disconnect the electrical connector: X2 @K33 HVAC Control Module
- Ignition - On / Vehicle - In Service Mode
- Momentarily connect a 3 A fused jumper wire between the test points:Control circuit terminal 19 X2 & B+
Verify the component turns On and Off when connecting and disconnecting the jumper wire:E18 Rear Defogger Grid
- If the component does not turn On and Off
- Ignition/Vehicle - Off & Remove - Jumper wire(s)
- Disconnect the electrical connector: X2@X53A Fuse Block - Rear Body
- Ignition - On / Vehicle - In Service Mode
- Test for less than 1 V between the test points:Control circuit terminal 19 X2@Control module harness & Ground
- If 1 V or greater - Repair the short to voltage on the circuit.
- If less than 1 V
- Ignition/Vehicle - Off
- Test for infinite resistance between the test points:Control circuit terminal 19 X2 @Control module harness & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance
- Test for less than 2 ohms between the test points:Control circuit terminal 19 X2 @Control module harness & Terminal 40 X2@Fuse Block Harness
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Test or replace the component:X53A Fuse Block - Rear Body
- If the component turns On and Off
- Replace the component:K33 HVAC Control Module
NOTE:
It may take up to 2 min for all vehicle systems to power down before an accurate ground or low reference circuit continuity test can be performed.