Component Testing
- Ignition Off, disconnect the harness connector at the appropriate Q6 Camshaft Position Actuator Solenoid Valve.
- Test for 5 - 12 Ω between the control circuit terminal 1/A and the low reference circuit terminal 2/B of the Q6 Camshaft Position Actuator Solenoid Valve.
- If not between the specified values
Replace the Q6 Camshaft Position Actuator Solenoid Valve.
- If between the specified values
- If not between the specified values
- Test for infinite resistance between each terminal and the Q6 Camshaft Position Actuator Solenoid Valve housing.
- If less than infinite resistance
Replace the Q6 Camshaft Position Actuator Solenoid Valve.
- If infinite resistance
- If less than infinite resistance
- All OK.