Circuit/System Verification

  1. Ignition ON.
  2. Verify that no DTCs are set.
    • If no DTCs are set 
  3. Verify the scan tool Seat Function Select Switch parameter changes between Inactive and UP or Down when operating the switch.
    • If the parameter does not change 

      Test or replace the S64 Seat Adjuster Switch.

    • If the parameter changes 
  4. Verify the scan tool Seat 4-Way Switch parameter changes between Inactive and UP/Down or Forward/Rearward when operating the 4-way switch in the up/down and forward/rearward directions.
    • If the parameter does not change 

      Test or replace the S64 Seat Adjuster Switch.

    • If the parameter changes 
  5. Verify the scan tool Seat Massage Switch parameter changes between Active and Inactive when pressing the seat massage switch.
    • If the parameter does not change 

      Test or replace the S64 Seat Adjuster Switch.

    • If the parameter changes 
  6. Verify that all K134 Seat Bolster Memory Control Module functions operate when being controlled by the S64 Seat Adjuster Switch.
    • If all K134 Seat Bolster Memory Control Module functions are inoperative 

      Refer to Circuit/System Testing.

    • If any but not all of the K134 Seat Bolster Memory Control Module functions is inoperative 
    1. Ignition ON.
    2. Test the integrity of the air hoses and bladders for the inoperative lumbar/bolster function.
      • If a fault is found with the air hoses or bladders, repair or replace as needed.
      • If the air hoses and bladders test normal.
    3. Replace the K134 Seat Bolster Memory Control Module.
    • If all K134 Seat Bolster Memory Control Module functions operate 
  7. All OK.