Removal Procedure
- Disable the high voltage system. High Voltage Disabling
- Drain the power electronics and auxiliary radiator cooling system. Power Electronics and Auxiliary Radiator Drain and Fill (LTG HP9)
Generator Control Module Coolant Tank Hose Clamp (1) - Disengage - Hose Clamp Replacement Guidelines - Spring Type
- Generator Control Module Coolant Tank Hose (2)@Generator Control Module Coolant/Air Separator - Remove
Retainer (1)@Drive Motor Generator Control Module Coolant Pump Hose (2) - Disengage
- Drive Motor Generator Control Module Coolant Pump Hose (2)@Generator Control Module Coolant/Air Separator - Remove
Generator Control Module Coolant/Air Separator Bolt (1)@Generator Control Module Coolant/Air Separator - Remove
Generator Control Module Coolant/Air Separator (1)@Generator Control Module Coolant Radiator Bracket - Remove
- Generator Control Module Coolant/Air Separator (1) - Remove