Removal Procedure
- Command the Discharge Start/Stop Capacitor parameter with the scan tool and discharge the multifunction energy storage capacitor. Wait 3 minutes for the capacitor to discharge.
- Disconnect the battery negative cable. Battery Negative Cable Disconnection and Connection (with KL9)
- Rear Compartment Side Trim Replacement - Left Side - Remove
{If equipped} Active Safety Control Module Bracket Bolt (1) - Remove
- {If equipped} Active Safety Control Module Bracket (2) - Reposition away
Multifunction Energy Storage Capacitor Control Module Bracket Bolt (1) - Remove [2x]
- Multifunction Energy Storage Capacitor Control Module Bracket Bolt (3) - Remove [2x]
- Check the voltage at K176 Stop/Start Multifunction Energy Storage Capacitor Control Module terminal X3-A to Ground, verify it is less than 1 volt.
- If greater than 1 Volt, disconnect X3-A at C10 Stop/Start Multifunction Energy Storage Capacitor Control Module and apply electrical tape on the terminal to prevent discharge.
Auxiliary Generator Battery Jumper Cable Nut (1) - Remove [3x]
- Auxiliary Generator Battery Jumper Cable (2) - Remove [3x]
- Disconnect the electrical connectors. (3)
- Multifunction Energy Storage Capacitor Control Module (4) - Remove
Multifunction Energy Storage Capacitor Control Module Nut (1) - Remove [2x]
- Multifunction Energy Storage Capacitor Control Module Bracket (3) - Remove