Installation Procedure
Battery Monitor Module(3) - Install
- Battery Negative Post Clamp Nut(1) - Tighten 4.5 N.m (40 lb in)
- Electrical Connector(2) - Connect
Battery Negative Cable(3) - Install
- Use an open ended wrench to hold the battery sensor ground tab, while tightening the battery negative cable nut.(2)
- Battery Negative Cable Nut(1) - Tighten 12 N.m (106 lb in)
- Perform the battery sensor learn procedure. Battery Sensor Module Learn
CAUTION:
Refer to Fastener Caution