Circuit/System Verification
- Verify DTC B0052 00 is not set.
- Using the scan tool, select Control Module Self Test in Configuration/Reset Functions from the Multifunction Energy Storage Capacitor Control Module menu.
- Verify the Control Module Status transitions to Unlocked.
- If the Control Module Status does not transition to Unlock, replace the K186 Multifunction Energy Storage Capacitor Control Module.
- Go to next step: If the Control Module Status transitions to Unlock
- Clear the DTC. If the DTC will not clear, replace the K186 Multifunction Energy Storage Capacitor Control Module.
- Go to next step: If DTC B0052 00 is not set
- All OK.