Fastener Specifications
Reusable Threaded Fastener Tightening Specifications
|
NOTE:
All fasteners listed in this table can be reused after removal. |
|
|---|---|
| Application | Specification |
| Metric (English) | |
| Active Safety Control Module Bracket Bolt | 2.5 N.m (22 lb in) |
| Auxiliary Generator Battery Jumper Cable Nut (KL9) | 12 N.m (106 lb in) |
| Battery Fuse Block Battery Positive Cable Nut (LGX, LT4) | 15 N.m (11 lb ft) |
| Battery Hold Down Bracket Fastener | 9 N.m (80 lb in) |
| Battery Negative Cable @ Battery Sensor Module Nut (KL9) | 12 N.m (106 lb in) |
| Battery Negative Cable @ Ground Stud | 22 N.m (16 lb ft) |
| Battery Negative Cable Extension Cable @ Engine Block Ground Bolt (LF3) | 22 N.m (16 lb ft) |
| Battery Negative Cable Extension Cable @ Engine Block Ground Fastener (LGX) | 22 N.m (16 lb ft) |
| Battery Negative Cable Extension Cable @ Front End Upper Tie Bar Extension Fastener (LF3, LGX) | 15 N.m (11 lb ft) |
| Battery Negative Cable Frame Ground @ Front End Upper Tie Bar Extension Fastener (LT4) | 15 N.m (11 lb ft) |
| Battery Negative Cable Ground @Engine Block Fastener (LT4) | 40 N.m (30 lb ft) |
| Battery Negative Post Clamp Nut (with KL9) | 7 N.m (62 lb in) |
| Battery Negative Post Clamp Nut (without KL9) | 7 N.m (62 lb in) |
| Battery Positive Barrel @ Pre-Fuse Block Fastener | 15 N.m (11 lb ft) |
| Battery Positive Cable @ Starter Solenoid Fastener (LTG) | 12.5 N.m (111 lb in) |
| Battery Positive Cable Fastener (LGX) | 6 N.m (53 lb in) |
| Battery Positive Cable Nut (LGX) | 15 N.m (11 lb ft) |
| Battery Positive Cable Nut (LT4) | 15 N.m (11 lb ft) |
| Battery Positive Cable Terminal @ Battery Fuse Block Stud Fastener | 12 N.m (106 lb in) |
| Battery Post Clamp Fastener | 7 N.m (62 lb in) |
| Body Harness Terminal @ Battery Negative Cable Fastener | 7 N.m (62 lb in) |
| Body Harness Terminal @ Battery Sensor Module (KL9) | 9 N.m (80 lb in) |
| Engine Harness Battery Positive Terminal @ Generator (LF3) | 15 N.m (11 lb ft) |
| Engine Harness Battery Positive Terminal @ Generator (LTG) | 22 N.m (16 lb ft) |
| Generator Bolt (LGX) | 22 N.m (16 lb ft) |
| Generator Bolt (LT4) | 58 N.m (43 lb ft) |
| Generator Mounting Fastener (LF3) | 58 N.m (43 lb ft) |
| Generator Mounting Fastener (LTG) | 22 N.m (16 lb ft) |
| Generator Mounting Stud (LTG) | 9 N.m (80 lb in) |
| Ground Cable Nut (KL9) | 12 N.m (106 lb in) |
| Multifunction Energy Storage Capacitor Control Module Bracket Bolt (KL9) | 9 N.m (80 lb in) |
| Multifunction Energy Storage Capacitor Control Module Nut (KL9) | 9 N.m (80 lb in) |
| Multifunction Energy Storage Capacitor Fastener | 9 N.m (80 lb in) |
| Starter Lower Mounting Fastener (LTG) | 22 N.m (16 lb ft) |
| Starter Heat Shield Fastener (LGX, LT4) | 9 N.m (80 lb in) |
| Starter Mounting Bolt (LGX) | 58 N.m (43 lb ft) |
| Starter Mounting Bolt (LT4) | 50 N.m (37 lb ft) |
| Starter Mounting Fastener (LF3) | 58 N.m (43 lb ft) |
| Starter Shield Fastener (LF3) | 4.7 N.m (42 lb in) |
| Starter Solenoid Cable @ Starter Solenoid Fastener (LF3, LTG) | 12.5 N.m (111 lb in) |
| Starter Solenoid Cable @ Starter Solenoid Fastener (LT4) | 12 N.m (106 lb in) |
| Starter Solenoid Cable @ Starter Solenoid Nut (LF3) | 12.5 N.m (111 lb in) |
| Starter Solenoid Cable @ Starter Solenoid Nut (LGX) | 12.5 N.m (111 lb in) |
| Starter Solenoid Cable @ Starter Solenoid Nut (LT4) | 12 N.m (106 lb in) |
| Starter Solenoid Cable Conduit Fastener (LGX) | 9 N.m (80 lb in) |
| Starter Solenoid Cable Fastener (LF3) | 6 N.m (53 lb in) |
| Starter Solenoid Cable Ground @ Engine Block Fastener (LTG) | 45 N.m (33 lb ft) |
| Starter Solenoid Cable Ground @ Upper Tie Bar Frame Extension Rail Fastener (LTG) | 11 N.m (97 lb in) |
| Starter Solenoid Cable Nut (LGX) | 12.5 N.m (111 lb in) |
| Starter Solenoid Cable Nut (LT4) | 12 N.m (106 lb in) |
| Starter Upper Mounting Fastener (LTG) | 22 N.m (16 lb ft) |