Installation Procedure
Clean the sealing surfaces of the EBCM and the BPMV with denatured alcohol and allow to dry.
- Inspect the EBCM to BPMV gasket for damage and replace, if necessary.
- Install the EBCM (1) to the BPMV.
- CAUTION:NOTE:
A new EBCM may not have threaded inserts. Refer to the Electronic Parts Catalog and use new self tapping fasteners to form the threads.
Install the EBCM bolts (1) and tighten in a cross pattern to 3 N.m (27 lb in).
- Connect the EBCM electrical connector.
- Program the EBCM. Control Module References