Circuit/System Testing

  1. Ignition OFF, measure and record the C1 Battery voltage at the terminals.
  2. Verify the measured voltage is between 12.0 - 15.0 V.
    • Go to next step: If voltage is between 12.0 - 15.0 V 
  3. Test for less than 0.5 V between the positive battery terminal and positive terminal at the X50D Fuse Block - Battery with the ignition in the CRANK/START position.
    • If 0.5 V or greater 

      Replace the positive battery cable.

    • Go to next step: If less than 0.5 V 
  4. Test for less than 0.5 V between the positive battery cable at the X50D Fuse Block - Battery and the Terminal 1 X2 or A X2 at the M64 Starter Motor with the ignition in the CRANK/START position.
    • If 0.5 V or greater 

      Replace the positive battery cable.

    • Go to next step: If less than 0.5 V 
  5. Test for less than 0.5 V between the negative battery cable and the M64 Starter Motor Case with the ignition in the CRANK/START position.
    • If 0.5 V or greater 

      Replace the negative battery cable.

    • Go to next step: If less than 0.5 V 
  6. Replace the Battery.