LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2019 >> XT5 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 117 (Component Connector End Views (F106P-K20)) >> Component Connector End Views >> K9 Body Control Module X2
April 5, 2026: LEMON Manuals is launched! Read the announcement.

K9 Body Control Module X2

WARNING: This page is about a different car, the 2019 Chevrolet Malibu. However, it is still accessible from the selected car via links, so may be relevant.
GM2537269Courtesy of GENERAL MOTORS COMPANY
Connector Part Information
  • Harness Type: Instrument Panel
  • OEM Connector: 13824336
  • Service Connector: 13576032
  • Description: 27-Way F 0.64, 2.8 Series (BU)
Terminal Part Information

Terminal Type ID Terminated Lead Diagnostic Test Probe Terminal Removal Tool Service Terminal Tray Name Core Crimp Insulation Crimp
I 13582297 J-35616-64B (LT BU) J-38125-215A Not Available Not Available Not Available Not Available
II 13582326 J-35616-35 (VT) J-38125-553 8100-4444 Sumitomo 22 2 A
Pin Size Color Circuit Function Terminal Type ID Option
1 0.75 RD/BN 4240 Battery Positive Voltage II -
2 1 BK 1850 Ground II -
3 - - - Not Occupied - -
4 1 RD/BN 4940 Battery Positive Voltage II -
5 0.35 GY 157 Interior Lamp Control I -
6 - - - Not Occupied - -
7 0.35 BU/YE 5361 Brake Apply Sensor Signal I -
8 0.35 YE 6817 LED Backlight Dimming Control I -
9 0.35 YE 44 Instrument Panel Lamp Dimmer Switch Signal I -
10 0.13 WH 278 Ambient Light Sensor Signal I -
11 0.13 YE 5526 Tap Up/Tap Down Switch Signal I -
12 - - - Not Occupied - -
13 0.35 WH 5359 Brake Apply Sensor Control I -
14 0.35 BU/VT 1788 Traction Control Switch Signal 1 I -
15 - 16 - - - Not Occupied - -
17 0.13 VT 5723 Ignition Mode Switch Mode Voltage I -
18 0.13 GY 3849 High Beam Auto On/Off Switch Signal I -
19 0.35 GN 4512 Wireless Charging System Charge Indicator Control I -
20 - - - Not Occupied - -
21 0.35 GN/GY 6135 Local Interconnect Network Serial Data Bus 4 I -
22 0.35 GN 5060 Low Speed GMLAN Serial Data I -
23 - 24 - - - Not Occupied - -
25 0.35 GY/WH 3272 Remote Function Actuator Control I -
26 0.13 GN 111 Hazard Switch Signal I -
27 0.13 YE 3274 Remote Function Actuator Transmit Signal I -